Literature DB >> 9949736

Use of poly(tetrafluoroethylene)s as a sample support for the MALDI-TOF analysis of DNA and proteins.

K C Hung1, H Ding, B Guo.   

Abstract

Matrix-assisted laser desorption/ionization mass spectrometry of DNA and proteins, directly deposited on the poly(tetrafluoroethylene) (Teflon) surface, is demonstrated. For DNA analysis, this technique apparently produces a more homogeneous coverage of the matrix/DNA over the sample surface. Moreover, it enhances the sensitivity and salt tolerance. As described here, this technique can also achieve an excellent mass resolution, similar to that observed using a metal probe for DNA up to 62mer. We also examined the use of Teflon as a sample support for protein analysis since Teflon has been used as a transfer membrane. Less than 25 fmol of myoglobin has been detected with this technique. In addition, effective MALDI-TOF analysis of salt-contaminated protein samples can also be accomplished by loading the protein sample onto Teflon, followed by steps of washing away salts, adding the matrix, and desorbing sample directly from Teflon.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9949736     DOI: 10.1021/ac980824n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Direct genetic analysis by matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  T J Griffin; J G Hall; J R Prudent; L M Smith
Journal:  Proc Natl Acad Sci U S A       Date:  1999-05-25       Impact factor: 11.205

2.  Improving the signal intensity and sensitivity of MALDI mass spectrometry by using nanoliter spots deposited by induction-based fluidics.

Authors:  Tingting Tu; Andrew D Sauter; Andrew D Sauter; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-08       Impact factor: 3.109

3.  Sugar additives for MALDI matrices improve signal allowing the smallest nucleotide change (A:T) in a DNA sequence to be resolved.

Authors:  M Shahgholi; B A Garcia; N H Chiu; P J Heaney; K Tang
Journal:  Nucleic Acids Res       Date:  2001-10-01       Impact factor: 16.971

4.  Coupling sodium dodecyl sulfate-capillary polyacrylamide gel electrophoresis with matrix-assisted laser desorption ionization time-of-flight mass spectrometry via a poly(tetrafluoroethylene) membrane.

Authors:  Joann J Lu; Zaifang Zhu; Wei Wang; Shaorong Liu
Journal:  Anal Chem       Date:  2011-02-10       Impact factor: 6.986

5.  Optimized sample-processing time and peptide recovery for the mass spectrometric analysis of protein digests.

Authors:  Doris E Terry; Edward Umstot; Dominic M Desiderio
Journal:  J Am Soc Mass Spectrom       Date:  2004-06       Impact factor: 3.109

6.  Miniaturizing sample spots for matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Tingting Tu; Michael L Gross
Journal:  Trends Analyt Chem       Date:  2009-08-01       Impact factor: 12.296

7.  Importance of the matrix and the matrix/sample ratio in MALDI-TOF-MS analysis of cathelicidins obtained from porcine neutrophils.

Authors:  Anna Smolira; Joanna Wessely-Szponder
Journal:  Appl Biochem Biotechnol       Date:  2014-11-29       Impact factor: 2.926

8.  Simple and Environmentally Friendly Fabrication of Superhydrophobic Alkyl Ketene Dimer Coated MALDI Concentration Plates.

Authors:  Joakim Romson; Johan Jacksén; Åsa Emmer
Journal:  J Am Soc Mass Spectrom       Date:  2017-04-12       Impact factor: 3.109

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.