Literature DB >> 9949399

Physical characteristics of a miniature multileaf collimator.

P Xia1, P Geis, L Xing, C Ma, D Findley, K Forster, A Boyer.   

Abstract

A preliminary study of the physical characteristics of a miniature multileaf collimator (mMLC) used with 4 MV x rays is reported. The mMLC attached to the accessory mount of a class C or D Varian linear accelerator (Varian Oncology Systems, Palo Alto, CA) with a source to aperture distance of 65 cm. The field penumbra using the small leaves was found to be consistent with the anticipated field penumbra using photon jaws at the same source to aperture distance as the mMLC. The percentage depth dose values of square fields were found to be consistent with the fields collimated with the upper and lower jaws. Output factors for the very small fields were found to vary rapidly. Circular fields could be produced with depth dose characteristics similar to those produced using conical tertiary collimators, commonly used for radiosurgery, but with a broader penumbra.

Entities:  

Mesh:

Year:  1999        PMID: 9949399     DOI: 10.1118/1.598478

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

2.  Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.

Authors:  L Wang; B Movsas; R Jacob; E Fourkal; L Chen; R Price; S Feigenberg; A Konski; A Pollack; C Ma
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

3.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

4.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

5.  An integrated treatment delivery system for CSRS and CSRT and clinical applications.

Authors:  A Shiu; B Parker; J-S Ye; J Lii
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.