Literature DB >> 9934753

Use of a push enteroscope improves ability to perform total colonoscopy in previously unsuccessful attempts at colonoscopy in adult patients.

G R Lichtenstein1, P D Park, W B Long, G G Ginsberg, M L Kochman.   

Abstract

OBJECTIVE: Total colonoscopy with use of a standard adult colonoscope can be difficult in the presence of a redundant or angulated colon. It is often possible to traverse these areas with the use of a thinner, more flexible endoscope. The objective of this study was to evaluate the efficacy of completing total colonoscopy using a push enteroscope when a standard colonoscope was unsuccessful.
METHODS: A prospective analysis was performed for 721 consecutive colonoscopies attempted by two gastroenterologists. Those patients in whom complete colonoscopy was unsuccessful using the standard colonoscope (Olympus CF-100L) had attempts to complete colonoscopy using the enteroscope (Olympus SIF-100). The extent of each exam was recorded. Additional pathologic findings discovered by the use of the enteroscope and therapeutic interventions performed were additionally noted.
RESULTS: Colonoscopy using an enteroscope was performed in 32 patients with successful total colonoscopy in 22 patients (68.7%). Additional pathology was noted in nine patients who had successful complete colonoscopy using the enteroscope; adenomatous polyp (n = 5), adenocarcinoma (n = 1), bleeding source (n = 2), and extent of colitis (n = 1). Total colonoscopy rate using standard adult colonoscope was 93.2% (630 of 676) when cases with poor bowel preparation (n = 23) and obstructing lesions (n = 14) were excluded. When the results of successful colonoscopies with the enteroscope were included, the overall completion rate of total colonoscopy improved to 96.4% (652 of 676).
CONCLUSION: The use of the enteroscope to help evaluate patients who have had incomplete colonoscopies with the standard colonoscope increases the diagnostic yield of colonic examination.

Entities:  

Mesh:

Year:  1999        PMID: 9934753     DOI: 10.1111/j.1572-0241.1999.00794.x

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  8 in total

1.  Colonoscopy using a small-caliber colonoscope with passive-bending after incomplete colonoscopy due to sharp angulation or pain.

Authors:  Koichiro Sato; Fumiko Shigiyama; Sayo Ito; Tomoyuki Kitagawa; Kenji Tominaga; Takeshi Suzuki; Iruru Maetani
Journal:  Surg Endosc       Date:  2013-05-31       Impact factor: 4.584

2.  Incomplete colonoscopy: maximizing completion rates of gastroenterologists.

Authors:  Mayur Brahmania; Jei Park; Sigrid Svarta; Jessica Tong; Ricky Kwok; Robert Enns
Journal:  Can J Gastroenterol       Date:  2012-09       Impact factor: 3.522

3.  Prospective comparison of an adult, an intermediate pediatric and a long pediatric colonoscope in the training process of gastrointestinal fellows to achieve high-quality practice in colonoscopy.

Authors:  George Tribonias; Athanasios-Dimitrios Bacasis; Yoriaki Komeda; George Lyrakos; Ioannis Giotis; Niki Daferera; Dimitrios Charisis; Margarita-Eleni Manola; Dimitrios Karapiperis
Journal:  Ann Gastroenterol       Date:  2022-05-12

4.  Transparent hood attached to the colonoscope: does it really work for all types of colonoscopes?

Authors:  Takashi Shida; Yosuke Katsuura; Osamu Teramoto; Makoto Kaiho; Shigetsugu Takano; Hiroyuki Yoshidome; Masaru Miyazaki
Journal:  Surg Endosc       Date:  2008-02-23       Impact factor: 4.584

5.  Routine colonoscopy with a standard gastroscope. A randomized comparative trial in a western population.

Authors:  Till Wehrmann; Izabel Lechowicz; Ksenia Martchenko; Andrea Riphaus
Journal:  Int J Colorectal Dis       Date:  2008-04       Impact factor: 2.571

6.  Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy.

Authors:  Kiyonori Kobayashi; Miyuki Mukae; Taishi Ogawa; Kaoru Yokoyama; Miwa Sada; Wasaburo Koizumi
Journal:  World J Gastrointest Endosc       Date:  2013-03-16

7.  Double-Balloon Endoscopy after Incomplete Colonoscopy and Its Comparison with Computed Tomography Colonography.

Authors:  Carlijn Hermans; Dennis van der Zee; Lennard Gilissen
Journal:  Clin Endosc       Date:  2018-01-10

8.  Prospective evaluation of the motorized spiral enteroscope for previous incomplete colonoscopy.

Authors:  Abdulbaqi Al-Toma; Dorien M Oude Hergelink; Jacco Tenthof van Noorden; Jan Jacob Koornstra
Journal:  Endosc Int Open       Date:  2022-08-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.