Literature DB >> 9931217

Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation.

J M Beach1, K J Schwenzer, S Srinivas, D Kim, J S Tiedeman.   

Abstract

A method for noninvasive measurement of Hb O2 saturation (SO2) in retinal blood vessels by digital imaging was developed and tested. Images of vessels were recorded at O2-sensitive and O2-insensitive wavelengths (600 and 569 nm, respectively) by using a modified fundus camera with an image splitter coupled to an 18-bit digital camera. Retinal arterial SO2 was varied experimentally by having subjects breathe mixtures of O2 and N2 while systemic arterial SO2 was monitored with a pulse oximeter. Optical densities (ODs) of vascular segments were determined using a computer algorithm to track the path of reflected light intensity along vessels. During graded hypoxia the OD ratio (ODR = OD600/OD569) bore an inverse linear relationship to systemic SO2. Compensation for the influence of choroidal pigmentation significantly reduced variation in the arterial SO2 measurements among subjects. An O2 sensitivity of 0.00504 +/- 0.00029 (SE) ODR units/%SO2 was determined. Retinal venous SO2 at normoxia was 55 +/- 3.38% (SE). Breathing 100% O2 increased venous SO2 by 19.2 +/- 2.9%. This technique, when combined with blood flow studies in human subjects, will enable the study of retinal O2 utilization under experimental and various disease conditions.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9931217     DOI: 10.1152/jappl.1999.86.2.748

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  54 in total

1.  Oximetry with a multiple wavelength SLO.

Authors:  R A Ashman; F Reinholz; R H Eikelboom
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Retinal oximeter for the blue-green oximetry technique.

Authors:  Kurt R Denninghoff; Katarzyna B Sieluzycka; Jennifer K Hendryx; Tyson J Ririe; Lawrence Deluca; Russell A Chipman
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

3.  Relationships between visual field sensitivity and spectral absorption properties of the neuroretinal rim in glaucoma by multispectral imaging.

Authors:  Jonathan Denniss; Ingo Schiessl; Vincent Nourrit; Cecilia H Fenerty; Ramesh Gautam; David B Henson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-07       Impact factor: 4.799

4.  Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography.

Authors:  Larry Kagemann; Gadi Wollstein; Maciej Wojtkowski; Hiroshi Ishikawa; Kelly A Townsend; Michelle L Gabriele; Vivek J Srinivasan; James G Fujimoto; Joel S Schuman
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

5.  Reliability of vessel diameter measurements with a retinal oximeter.

Authors:  Renata Blondal; Margret Kara Sturludottir; Sveinn Hakon Hardarson; Gisli Hreinn Halldorsson; Einar Stefánsson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-04-16       Impact factor: 3.117

6.  A method for volumetric retinal tissue oxygen tension imaging.

Authors:  Anthony E Felder; Justin Wanek; Pang-Yu Teng; Norman P Blair; Mahnaz Shahidi
Journal:  Curr Eye Res       Date:  2017-09-28       Impact factor: 2.424

7.  Retinal vessel oxygen saturation and vessel diameter in retinitis pigmentosa at various ages.

Authors:  Yao Zong; Leilei Lin; Changxian Yi; Xia Huang; Yue Fu; Yanmin Dong; Xiaobing Qian; Yujie Li; Qianying Gao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-08       Impact factor: 3.117

8.  Investigation of blood flow regulation and oxygen saturation of the retinal vessels in primary open-angle glaucoma.

Authors:  L Ramm; S Jentsch; S Peters; R Augsten; M Hammer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-12       Impact factor: 3.117

9.  Automatic analysis of normative retinal oximetry images.

Authors:  J R Harish Kumar; Chandra Sekhar Seelamantula; Ashwin Mohan; Rohit Shetty; T J M Berendschot; Carroll A B Webers
Journal:  PLoS One       Date:  2020-05-18       Impact factor: 3.240

10.  Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes.

Authors:  Jason G Dwight; Christina Y Weng; Robert E Coffee; Michal E Pawlowski; Tomasz S Tkaczyk
Journal:  Int Ophthalmol Clin       Date:  2016
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.