Literature DB >> 32421691

Automatic analysis of normative retinal oximetry images.

J R Harish Kumar1,2, Chandra Sekhar Seelamantula1, Ashwin Mohan3, Rohit Shetty3, T J M Berendschot4, Carroll A B Webers4.   

Abstract

Retinal oximetry is an important screening tool for early detection of retinal pathologies due to changes in the vasculature and also serves as a useful indicator of human-body-wide vascular abnormalities. We present an automatic technique for the measurement of oxygen saturation in retinal arterioles and venules using dual-wavelength retinal oximetry images. The technique is based on segmenting an optic-disc-centered ring-shaped region of interest and subsequent analysis of the oxygen saturation levels. We show that the two dominant peaks in the histogram of the oxygen saturation levels correspond to arteriolar and venular oxygen saturations from which the arterio-venous saturation difference (AVSD) can be calculated. For evaluation, we use a normative database of Asian Indian eyes containing 44 dual-wavelength retinal oximetry images. Validations against expert manual annotations of arterioles and venules show that the proposed technique results in an average arteriolar oxygen saturation (SatO2) of 87.48%, venular SatO2 of 57.41%, and AVSD of 30.07% in comparison with the expert ground-truth average arteriolar SatO2 of 89.41%, venular SatO2 of 56.32%, and AVSD of 33.09%, respectively. The results exhibit high consistency across the dataset indicating that the automated technique is an accurate alternative to the manual procedure.

Entities:  

Year:  2020        PMID: 32421691      PMCID: PMC7233590          DOI: 10.1371/journal.pone.0231677

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  38 in total

1.  Retinal large vessel oxygen saturations correlate with early blood loss and hypoxia in anesthetized swine.

Authors:  K R Denninghoff; M H Smith; R A Chipman; L W Hillman; P M Jester; C E Hughes; F Kuhn; L W Rue
Journal:  J Trauma       Date:  1997-07

2.  Rim-to-Disc Ratio Outperforms Cup-to-Disc Ratio for Glaucoma Prescreening.

Authors:  J R Harish Kumar; Chandra Sekhar Seelamantula; Yogish Subraya Kamath; Rajani Jampala
Journal:  Sci Rep       Date:  2019-05-08       Impact factor: 4.379

Review 3.  Cellular and physiological mechanisms underlying blood flow regulation in the retina and choroid in health and disease.

Authors:  Joanna Kur; Eric A Newman; Tailoi Chan-Ling
Journal:  Prog Retin Eye Res       Date:  2012-05-03       Impact factor: 21.198

4.  Validation of human whole blood oximetry, using a hyperspectral fundus camera with a model eye.

Authors:  David J Mordant; Ied Al-Abboud; Gonzalo Muyo; Alistair Gorman; Ahmed Sallam; Paul Rodmell; John Crowe; Steve Morgan; Peter Ritchie; Andrew R Harvey; Andrew I McNaught
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-27       Impact factor: 4.799

5.  Effects of optic atrophy on retinal blood flow and oxygen saturation in humans.

Authors:  J Sebag; F C Delori; G T Feke; J J Weiter
Journal:  Arch Ophthalmol       Date:  1989-02

Review 6.  Oxygen transport by hemoglobin.

Authors:  Heimo Mairbäurl; Roy E Weber
Journal:  Compr Physiol       Date:  2012-04       Impact factor: 9.090

7.  Retinal oxygen saturation is altered in diabetic retinopathy.

Authors:  Sveinn Hakon Hardarson; Einar Stefánsson
Journal:  Br J Ophthalmol       Date:  2011-11-11       Impact factor: 4.638

8.  Diabetic patients with retinopathy show increased retinal venous oxygen saturation.

Authors:  Martin Hammer; Walthard Vilser; Thomas Riemer; Aleksandra Mandecka; Dietrich Schweitzer; Uta Kühn; Jens Dawczynski; Fanny Liemt; Jürgen Strobel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-04-29       Impact factor: 3.117

9.  Retinal vessel oxygen saturation under flicker light stimulation in patients with nonproliferative diabetic retinopathy.

Authors:  Martin Hammer; Tabitha Heller; Susanne Jentsch; Jens Dawczynski; Dietrich Schweitzer; Sven Peters; Kai-Uwe Schmidtke; Ulrich-Alfons Müller
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-26       Impact factor: 4.799

10.  Normative database of retinal oximetry in Asian Indian eyes.

Authors:  Ashwin Mohan; Supriya Dabir; Naresh Kumar Yadav; Matthew Kummelil; Rajesh S Kumar; Rohit Shetty
Journal:  PLoS One       Date:  2015-04-29       Impact factor: 3.240

View more
  1 in total

1.  Automation improves repeatability of retinal oximetry measurements.

Authors:  Robert Arnar Karlsson; Olof Birna Olafsdottir; Vedis Helgadottir; Soumaya Belhadj; Thorunn Scheving Eliasdottir; Einar Stefansson; Sveinn Hakon Hardarson
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.