Literature DB >> 9930412

Twenty-year follow-up of the Hancock modified orifice porcine aortic valve.

L H Cohn1, J J Collins, R J Rizzo, D H Adams, G S Couper, S F Aranki.   

Abstract

BACKGROUND: The entire experience with the Hancock modified orifice porcine bioprosthetic aortic valve from 1976 to 1996 at the Brigham and Women's Hospital has been reviewed. Eight hundred forty-three patients received this valve with a total follow-up of 61,114 months, and a mean follow-up of approximately 72.5 months. There were 490 men and 353 women, and the predominate lesion was aortic stenosis (636 of 843); 365 (43%) patients required a concomitant coronary artery bypass graft operation.
METHODS: Patients were followed prospectively in the Brigham Cardiac Valve Data Registry, and the data were analyzed by the SAS statistical package, using actuarial survival curves and incidence per patient-year of morbidity and mortality.
RESULTS: The overall operative mortality was 45 of 843 (5.3%) with 23 of 478 (4.8%) for isolated aortic valve replacement and 22 of 365 (6.0%) for aortic valve plus coronary artery bypass graft operation. The major morbidity of this valve was structural valve dysfunction, which was significantly related to the age of the patient in whom the valve was placed. Actuarial probability of freedom from structural valve degeneration at 5, 10, and 15 years overall was 99%+/-1%, 79%+/-3% and 57%+/-4%, at 15 years, respectively. In patients younger than 50 years, freedom from structural valve dysfunction was 16%+/-8%, whereas in the age group older than 70 years it was 87%+/-5% (p = 0.0005). Thromboembolism at 10 and 15 years was 81%+/-3% overall, 84%+/-2% in patients in normal sinus rhythm, and 57%+/-13% in patients with chronic atrial fibrillation.
CONCLUSIONS: The Hancock modified orifice aortic valve, despite its more complicated fabrication, has been a reliable porcine bioprosthetic valve and can be used reliably in patients older than 70 years because of its low structural valve degeneration rate, and protection from stroke and anticoagulant hemorrhage in those patients in sinus rhythm.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9930412     DOI: 10.1016/s0003-4975(98)01105-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  8 in total

Review 1.  Should patients with asymptomatic mild or moderate aortic stenosis undergoing coronary artery bypass surgery also have valve replacement for their aortic stenosis?

Authors:  S H Rahimtoola
Journal:  Heart       Date:  2001-03       Impact factor: 5.994

Review 2.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

3.  Choice of prosthetic heart valve in a developing country.

Authors:  Shiv Kumar Choudhary; Sachin Talwar; Balram Airan
Journal:  Heart Asia       Date:  2016-04-28

4.  Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation.

Authors:  J P A Puvimanasinghe; J J M Takkenberg; M B Edwards; M J C Eijkemans; E W Steyerberg; L A Van Herwerden; K M Taylor; G L Grunkemeier; J D F Habbema; A J J C Bogers
Journal:  Heart       Date:  2004-10       Impact factor: 5.994

Review 5.  Heart valve replacement: which valve for which patient?

Authors:  Joseph Huh; Faisal Bakaeen
Journal:  Curr Cardiol Rep       Date:  2006-03       Impact factor: 2.931

6.  Calcification and Oxidative Modifications Are Associated With Progressive Bioprosthetic Heart Valve Dysfunction.

Authors:  Suengwon Lee; Robert J Levy; Abigail J Christian; Stanley L Hazen; Nathan E Frick; Eric K Lai; Juan B Grau; Joseph E Bavaria; Giovanni Ferrari
Journal:  J Am Heart Assoc       Date:  2017-05-08       Impact factor: 5.501

7.  Effect of Rosuvastatin on Bovine Pericardial Aortic Tissue Valve Calcification in a Rat Subdermal Implantation Model.

Authors:  Seung Hyun Lee; Dae-Hyun Kim; Young-Nam Youn; Sak Lee; Hyun Chel Joo; Byung Chul Chang; Kyung-Jong Yoo
Journal:  Korean Circ J       Date:  2017-05-25       Impact factor: 3.243

8.  Comparison of warfarin versus antiplatelet therapy after surgical bioprosthetic aortic valve replacement.

Authors:  Christina Christersson; Stefan K James; Lars Lindhagen; Anders Ahlsson; Örjan Friberg; Anders Jeppsson; Elisabeth Ståhle
Journal:  Heart       Date:  2019-11-22       Impact factor: 5.994

  8 in total