Literature DB >> 9926956

Temporal changes of periprosthetic bone density in patients with a modular noncemented femoral prosthesis.

L Rosenthall1, J D Bobyn, C E Brooks.   

Abstract

Bone mineral density changes surrounding a porous-coated proximal modular sleeved hip prosthesis were determined as a function of time over a 24-month period. The periprosthetic bone regions were defined by the 7 Gruen zones. Measurements were obtained with a dual-energy x-ray densitometer using a dedicated software program. Inclusion criteria required that the patients had primary implants, were asymptomatic with Harris hip scores of > or =95 for the duration of the study, and showed no radiographic evidence of loosening. The protocol specified that bone measurements be obtained within 1 week after surgery as a baseline reference and at 3, 6, 9, 12, 18, and 24 months thereafter. A total of 111 consecutive patients were enrolled in this ongoing prospective study, of whom 52 had 4 or more measurements after the initial baseline determination for statistical analysis. At 3 months, all zones showed a significant decrease in bone mineral density relative to the baseline measurements, and their mean loss ranged from 6.5% to 11.2%. By 24 months, mineral losses relative to baseline varied from 0 to 11% for Gruen zones 1 to 6. Relative to the 3-month levels, there was no significant change in zones 1, 4, and 6; a significant improvement in zones 3 and 5; and a small but significant loss in zone 2 at 24 months. Gruen zone 7, the medial femoral neck cortex, differed in that it was the site of greatest bone mineral loss, attaining a mean of 20.2% at 24 months. It was found that the amount of periprosthetic mineral loss at 12 months was independent of the initial baseline reference bone mineral levels. Results of this study show the normal temporal bone mineral changes surrounding a proximally modular porouscoated femoral implant. The pattern of change demonstrated may be peculiar to the prosthesis used in this study because it might differ in implants of different design and material composition.

Entities:  

Mesh:

Year:  1999        PMID: 9926956     DOI: 10.1016/s0883-5403(99)90205-x

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss.

Authors:  A I A Rahmy; T Gosens; G M Blake; A Tonino; I Fogelman
Journal:  Osteoporos Int       Date:  2003-12-06       Impact factor: 4.507

2.  Changes of bone mineral density after cementless total hip arthroplasty with two different stems.

Authors:  Keiji Sano; Kouji Ito; Kengo Yamamoto
Journal:  Int Orthop       Date:  2007-01-16       Impact factor: 3.075

3.  Late remodeling around a proximally HA-coated tapered titanium femoral component.

Authors:  William N Capello; James A D'Antonio; Rudolph G Geesink; Judy R Feinberg; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2008-10-11       Impact factor: 4.176

4.  Progressive femoral cortical and cancellous bone density loss after uncemented tapered-design stem fixation.

Authors:  Lutz A Mueller; Tobias E Nowak; Lothar Haeberle; Lars P Mueller; Alexander Kress; Michael Voelk; David Pfander; Raimund Forst; Rainer Schmidt
Journal:  Acta Orthop       Date:  2010-04       Impact factor: 3.717

5.  Alendronate inhibits periprosthetic bone loss around uncemented femoral components.

Authors:  Takashi Nishioka; Shoji Yagi; Tadashi Mitsuhashi; Masafumi Miyamoto; Tatsuya Tamura; Toru Kobayashi; Tetsuya Enishi
Journal:  J Bone Miner Metab       Date:  2007-04-20       Impact factor: 2.626

6.  Total hip arthroplasty using S-ROM prosthesis for dysplastic hip.

Authors:  Joon Soon Kang; Kyoung Ho Moon; Ryuh Sup Kim; Seung Rim Park; Jung Sun Lee; Sang Hyun Shin
Journal:  Yonsei Med J       Date:  2011-07       Impact factor: 2.759

7.  Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.

Authors:  Per Y Adolphson; Mats O F Salemyr; Olof G Sköldenberg; Henrik S G Bodén
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.