Literature DB >> 9922424

Marginal gap of crowns made with a phosphate-bonded investment and accelerated casting method.

E R Schilling1, B H Miller, R D Woody, A W Miller, M E Nunn.   

Abstract

STATEMENT OF PROBLEM: Numerous materials and methods have been used for complete crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-hour process before completion. Accelerated laboratory techniques have been used, but may not result in castings with equal marginal accuracy.
PURPOSE: This study measured the marginal gap and determined the clinical acceptability of single castings invested in a phosphate-bonded investment with the use of conventional and accelerated methods.
MATERIAL AND METHODS: Forty-four individual stone casts were poured from impressions made from a master die. Conventional and accelerated methods of investing and casting were followed in the fabrication of 44 single-unit castings. Twenty-two casts were used in each of the 2 groups. Each casting and its respective stone die were examined with a microscope at 4 predetermined sites. Perpendicular and 25-degree tilted measurements of marginal gap were documented for each. Evidence of marginal gap was then evaluated by t test.
RESULTS: Measurements recorded on the perpendicular and on a 25-degree tilt showed no statistically significant difference between conventional and accelerated groups. All gap measurements except one were within the range of clinical acceptability. The measurements revealed that conventional and accelerated perpendicular gap means were 13.2 and 13.6 microm, respectively, and the average tilted gap means were 31.6 and 32.2 microm, respectively.
CONCLUSIONS: A phosphate-bonded investment (Ceramigold) selected for an accelerated casting technique produced single castings within 30 minutes with marginal gaps comparable to those found that used conventional methods.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9922424     DOI: 10.1016/s0022-3913(99)70239-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Investigation of marginal fit and surface roughness of crowns, due to different bench set and different burnout temperature using base metal alloy.

Authors:  Anurag Hasti; Narendra P Patil
Journal:  J Indian Prosthodont Soc       Date:  2010-12-15

2.  Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

Authors:  J Brintha Jei; Jayashree Mohan
Journal:  J Indian Prosthodont Soc       Date:  2013-04-17

3.  Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

Authors:  Deepa Alex; Y Bharath Shetty; Glynis Anita Miranda; M Bharath Prabhu; Reshma Karkera
Journal:  J Indian Prosthodont Soc       Date:  2015 Jan-Mar

4.  Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness.

Authors:  Vivek Dattatray Jadhav; Bhagwan K Motwani; Jitendra Shinde; Prasad Adhapure
Journal:  Contemp Clin Dent       Date:  2017 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.