Literature DB >> 9917682

The impact of sterilization method on wear in knee arthroplasty.

I R Williams1, M B Mayor, J P Collier.   

Abstract

Sterilization by gamma irradiation in air has been shown to have the potential to accelerate the oxidation of polyethylene components resulting in reduced mechanical properties. In the hip, it has been reported that the occurrence of delamination and cracking in retrieved bearings is significantly different when comparing components sterilized with gamma irradiation in air with components sterilized with ethylene oxide. Using a collection of 1635 retrieved polyethylene knee bearings, this study pursues a similar comparison of sterilization method with clinical wear in the knee. It confirms that retrieved polyethylene knee components that were gamma irradiated in air have a high incidence of delamination and cracking, leading at times to complete wear through of the bearing. Knee components sterilized with ethylene oxide showed no evidence of fatigue damage even after in vivo durations in excess of 15 years.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9917682     DOI: 10.1097/00003086-199811000-00024

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

Authors:  John J Callaghan; Mitchell W Beckert; David W Hennessy; Devon D Goetz; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

2.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

3.  In vivo oxidation and surface damage in retrieved ethylene oxide-sterilized total knee arthroplasties.

Authors:  Daniel MacDonald; Josa Hanzlik; Peter Sharkey; Javad Parvizi; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  Routine surveillance of modular PFC TKA shows increasing failures after 10 years.

Authors:  Andrew S Malin; John J Callaghan; Kevin J Bozic; Steve S Liu; Devon D Goetz; Nicholas Sullivan; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2010-03-19       Impact factor: 4.176

Review 5.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 6.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25

7.  The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements.

Authors:  Raman Maiti; Raelene M Cowie; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-03-25       Impact factor: 1.617

8.  PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study.

Authors:  Claire L Brockett; Silvia Carbone; John Fisher; Louise M Jennings
Journal:  Wear       Date:  2017-03-15       Impact factor: 3.892

9.  Influence of conformity on the wear of total knee replacement: An experimental study.

Authors:  Claire L Brockett; Silvia Carbone; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-12-17       Impact factor: 1.617