Literature DB >> 9917609

Effect of increasing temperature on the properties of four bone cements.

M L Parks1, H A Walsh, E A Salvati, S Li.   

Abstract

This investigation uses a laboratory model to evaluate the effects of a heated femoral stem on the biomechanical properties of four common acrylic bone cements. American Society for Testing Materials dog bone shaped acrylic cement specimens made at four test temperatures, 0 degree C, 23 degrees C, 37 degrees C and 50 degrees C, were tested for modulus, ultimate tensile strength, fracture toughness, and percent porosity. Fatigue strength was tested in Simplex P at 23 degrees C and 37 degrees C. The data allow direct comparison among four cement brands at each of the four temperature conditions. No adverse changes of the mechanical properties were found for any cement at any temperature. Modulus, fracture toughness, and fatigue strength were unaffected by increased temperature. Ultimate tensile strength increased in Simplex P and Zimmer Osteobond but was unaffected for Zimmer Regular and Palacos R cements. Percent porosity was related to temperature changes inversely in all brands studied, except for Palacos R which consistently had low porosity, unaffected by temperature variation. Fatigue strength of Simplex P was unaffected by heating to 37 degrees C. Based on this laboratory model, heating of the femoral stem could save time without sacrificing mechanical properties of acrylic bone cement.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9917609     DOI: 10.1097/00003086-199810000-00025

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

2.  Altering polymerization temperature of antibiotic-laden cement can increase porosity and subsequent antibiotic elution.

Authors:  Jeffrey Sundblad; Mary Nixon; Nancy Jackson; Rahul Vaidya; David Markel
Journal:  Int Orthop       Date:  2018-09-15       Impact factor: 3.075

3.  Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Adriana Zoppi; Eduardo A Salvati
Journal:  Int Orthop       Date:  2006-03-31       Impact factor: 3.075

4.  Extending polymerization time of polymethylmethacrylate cement in percutaneous vertebroplasty with ice bath cooling.

Authors:  Ram Chavali; Rick Resijek; Steven K Knight; In Sup Choi
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

5.  Hypothermic manipulation of bone cement can extend the handling time during vertebroplasty.

Authors:  Po-Liang Lai; Ching-Lung Tai; I-Ming Chu; Tsai-Sheng Fu; Lih-Huei Chen; Wen-Jer Chen
Journal:  BMC Musculoskelet Disord       Date:  2012-10-16       Impact factor: 2.362

  5 in total