Literature DB >> 9917606

A critical look at cementless stems. Taper designs and when to use alternatives.

R B Bourne1, C H Rorabeck.   

Abstract

The clinical and radiographic efficacy of cementless taper design femoral components in total hip arthroplasty was determined. Cementless, taper design, femoral components have been shown to offer comparable clinical results to cemented femoral implants in a double blind, randomized, clinical trial. No differences were observed in terms of disease specific, patient specific, global health, functional capacity, or cost to utility outcome measures. The prevalence of pain in the thigh was the same in each group. Fixation of cementless, taper design, femoral stems depended on three-point fixation as shown on lateral radiographs. A clinical algorithm for femoral stem selection, based on more than 10 years experience with more than 1000 cementless, taper design femoral stems has been developed. Cementless, taper design, femoral implants currently are used in 75% of the authors' patients, provided they are younger than 75 years of age and have funnel shaped proximal femoral medullary canals. Cemented femoral stems are used in older patients, those who have cylindric medullary canals, and those who have inflammatory or unusual bone diseases (Paget's disease, previously irradiated bone).

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9917606

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

Authors:  Ryan G Molli; Adolph V Lombardi; Keith R Berend; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Ethnic and racial factors influencing well-being, perceived pain, and physical function after primary total joint arthroplasty.

Authors:  Carlos J Lavernia; Jose C Alcerro; Juan S Contreras; Mark D Rossi
Journal:  Clin Orthop Relat Res       Date:  2011-07       Impact factor: 4.176

3.  Clinical outcome and periprosthetic bone remodelling of an uncemented femoral component with taper design.

Authors:  Rainer Schmidt; Lutz Mueller; Tobias E Nowak; Rocco P Pitto
Journal:  Int Orthop       Date:  2003-04-12       Impact factor: 3.075

Review 4.  [Endoprosthetic treatment of osteoporosis-related coxarthrosis : aspects of safe patient treatment].

Authors:  S Kirschner; A Hartmann; K-P Günther; C Hamann
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

5.  Total Hip Arthroplasty by the Direct Anterior Approach Using a Neck-preserving Stem: Safety, efficacy and learning curve.

Authors:  Aditya Khemka; Omar Mograby; Sarah J Lord; Zelda Doyle; Munjed Al Muderis
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

6.  Comparison of periprosthetic bone remodeling after implantation of anatomic and tapered cementless femoral stems in total hip arthroplasty: A prospective cohort study protocol.

Authors:  Xiang-Dong Wu; Yu Chen; Zhang-Yu Wang; Yu-Jian Li; Zheng-Lin Zhu; Yu-Zhang Tao; Hong Chen; Qiang Cheng; Wei Huang
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.889

  6 in total