Literature DB >> 9895343

Whole blood capcellia CD4/CD8 immunoassay for enumeration of CD4+ and CD8+ peripheral T lymphocytes.

D Carrière1, J P Vendrell, C Fontaine, A Jansen, J Reynes, I Pagès, C Holzmann, M Laprade, B Pau.   

Abstract

We evaluated the Whole Blood Capcellia(R) CD4/CD8, an immunoenzymatic method that provides absolute counts of CD4+ and CD8+ T cells in peripheral blood. The assay is based on the separation of T cells by use of an anti-CD2 magnetic bead suspension, followed by reaction of the CD4 or CD8 molecules with the corresponding monoclonal antibody coupled to peroxidase. CD4-positive monocytes were excluded from the assay. Freeze-dried magnetic bead-T-cell complexes were used as calibrators. Capcellia counts from HIV-1-infected patients were compared with those obtained by flow cytometry as the comparison method. The results by Capcellia correlated well with those by flow cytometric analysis: r2 = 0.95; P <0.001; (y = 0.96x - 22.1); Sy|x = 64 for CD4; r2 = 0.81; P <0.001; (y = 1.26x - 76.4); Sy|x = 139 for CD8; n = 76. The correlation between CD4+ T-cell counts determined by two trained experimenters was significant (r2 = 0.96). Our results indicate that this new ELISA technique for lymphocyte immunophenotyping is an efficient alternative to flow cytometry.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9895343

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  A simple manual rosetting method for absolute CD4+ lymphocyte counting in resource-limited countries.

Authors:  Phonethipsavanh Nouanthong; Supansa Pata; Thira Sirisanthana; Watchara Kasinrerk
Journal:  Clin Vaccine Immunol       Date:  2006-05

2.  Correlation of CD4(+) T-Cell counts estimated by an immunocapture technique (Capcellia) with viral loads in human immunodeficiency virus-seropositive individuals.

Authors:  R Kannangai; S Ramalingam; M V Jesudason; T S Vijayakumar; O C Abraham; A Zachariah; G Sridharan
Journal:  Clin Diagn Lab Immunol       Date:  2001-11

3.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects.

Authors:  Xuanhong Cheng; Daniel Irimia; Meredith Dixon; Kazuhiko Sekine; Utkan Demirci; Lee Zamir; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2006-11-24       Impact factor: 6.799

4.  SMARThivCD4mos: a complexity-free and cost effective model technology for monitoring HIV patients CD4 number in resource-poor settings.

Authors:  Aboubakar Yari; Frederic S Passo; Venus Yari; Ousmane Sanni; Myra Yari; Mathieu Z Dovenou; Rachide Traore; Jean-Pierre Hounyet
Journal:  Bioinformation       Date:  2008-01-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.