Literature DB >> 9890844

Probable transmission of HIV from an orthopedic surgeon to a patient in France.

F Lot1, J C Séguier, S Fégueux, P Astagneau, P Simon, M Aggoune, P van Amerongen, M Ruch, M Cheron, G Brücker, J C Desenclos, J Drucker.   

Abstract

BACKGROUND: Transmission of HIV from infected health care workers to patients has been documented in only one cluster involving 6 patients of a dentist in Florida. In October 1995, the French Ministry of Health offered HIV testing to patients who had been operated on by an orthopedic surgeon in whom AIDS was recently diagnosed.
OBJECTIVE: To determine whether the surgeon transmitted HIV to patients during operations.
DESIGN: Epidemiologic investigation.
SETTING: The practice of an orthopedic surgeon in a French public hospital. PARTICIPANTS: 1 surgeon and 983 of his former patients. MEASUREMENTS: 3004 patients who had undergone invasive procedures were contacted by mail for counseling and HIV testing. One HIV-positive patient was interviewed, and DNA sequence analysis was performed to compare the genetic relation of the patient's and the surgeon's viruses. Infection-control precautions and the surgeon's practices were assessed.
RESULTS: Of 983 patients in whom serologic status was ascertained, 982 were HIV negative and 1 was HIV positive. The HIV-positive patient, a woman born in 1925, tested negative for HIV before placement of a total hip prosthesis with bone graft (a prolonged operation) performed by the surgeon in 1992. She had no identified risk for HIV exposure. Molecular analysis indicated that the viral sequences obtained from the surgeon and the HIV-infected woman were closely related. Infection-control precautions were in accordance with recommendations, but blood contact between the surgeon and his patients occurred commonly during surgical procedures.
CONCLUSIONS: An HIV-infected surgeon may have transmitted HIV to one of his patients during surgery.

Entities:  

Keywords:  Health Care and Public Health

Mesh:

Substances:

Year:  1999        PMID: 9890844     DOI: 10.7326/0003-4819-130-1-199901050-00002

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  15 in total

1.  Inadvertent prolonged fluid contact: an unappreciated professional risk for surgeons.

Authors:  J L Caillot; C Cote; E Voiglio; J Fabry
Journal:  Eur J Epidemiol       Date:  2000       Impact factor: 8.082

2.  Global impact of AIDS on work.

Authors:  Anne Cockcroft
Journal:  Occup Environ Med       Date:  2002-04       Impact factor: 4.402

3.  Effectiveness of the hands-free technique in reducing operating theatre injuries.

Authors:  B Stringer; C Infante-Rivard; J A Hanley
Journal:  Occup Environ Med       Date:  2002-10       Impact factor: 4.402

4.  No longer 'written off' - times have changed for the BBV-infected dental professional.

Authors:  J Bagg; K Roy; L Hopps; I Black; D Croser; C O'Halloran; F Ncube
Journal:  Br Dent J       Date:  2017-01-13       Impact factor: 1.626

Review 5.  Nosocomial spread of viral disease.

Authors:  C Aitken; D J Jeffries
Journal:  Clin Microbiol Rev       Date:  2001-07       Impact factor: 26.132

6.  Nosocomial transmission of bloodborne viruses from infected health care workers to patients.

Authors:  B Lynn Johnston; John M Conley
Journal:  Can J Infect Dis       Date:  2003-07

7.  Molecular evidence for nosocomial transmission of human immunodeficiency virus from a surgeon to one of his patients.

Authors:  A Blanchard; S Ferris; S Chamaret; D Guétard; L Montagnier
Journal:  J Virol       Date:  1998-05       Impact factor: 5.103

8.  Hepatitis C virus infection among transmission-prone medical personnel.

Authors:  H L Zaaijer; P Appelman; G Frijstein
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-11-03       Impact factor: 3.267

9.  The HIV-positive dentist: balancing the rights of the health care worker and the patient.

Authors:  M A Gardam; W F Flanagan; I E Salit
Journal:  CMAJ       Date:  2001-06-12       Impact factor: 8.262

10.  Surgeon-patient barrier efficiency monitored with an electronic device in three surgical settings.

Authors:  V R Hentz; M Stephanides; A Boraldi; R Tessari; R Isani; R Cadossi; R Biscione; L Massari; G C Traina
Journal:  World J Surg       Date:  2001-09       Impact factor: 3.352

View more