Literature DB >> 9889240

Comparison of NucliSens and Roche Monitor assays for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma.

J R Dyer1, C D Pilcher, R Shepard, J Schock, J J Eron, S A Fiscus.   

Abstract

We compared the performance of Organon Teknika's NucliSens and Roche Diagnostic Systems' Monitor quantitative human immunodeficiency type 1 RNA assays. Both had similar linearity and sensitivity over most of the dynamic range of the assays, although the Monitor assay was superior at the low range of RNA values while the NucliSens assay was more consistent at higher RNA values. NucliSens generally showed less interassay variability.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9889240      PMCID: PMC84337     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Viral load and disease progression in infants infected with human immunodeficiency virus type 1. Women and Infants Transmission Study Group.

Authors:  W T Shearer; T C Quinn; P LaRussa; J F Lew; L Mofenson; S Almy; K Rich; E Handelsman; C Diaz; M Pagano; V Smeriglio; L A Kalish
Journal:  N Engl J Med       Date:  1997-05-08       Impact factor: 91.245

Review 2.  Determinations of levels of human immunodeficiency virus type 1 RNA in plasma: reassessment of parameters affecting assay outcome. TUBE Meeting Workshop Attendees. Technology Utilization for HIV-1 Blood Evaluation and Standardization in Pediatrics.

Authors:  J Lew; P Reichelderfer; M Fowler; J Bremer; R Carrol; S Cassol; D Chernoff; R Coombs; M Cronin; R Dickover; S Fiscus; S Herman; B Jackson; J Kornegay; A Kovacs; K McIntosh; W Meyer; N Michael; L Mofenson; J Moye; T Quinn; M Robb; M Vahey; B Weiser; T Yeghiazarian
Journal:  J Clin Microbiol       Date:  1998-06       Impact factor: 5.948

Review 3.  Viral dynamics in HIV-1 infection.

Authors:  D Finzi; R F Siliciano
Journal:  Cell       Date:  1998-05-29       Impact factor: 41.582

4.  Quantification of HIV-1 RNA in plasma: comparable results with the NASBA HIV-1 RNA QT and the AMPLICOR HIV monitor test.

Authors:  A M Vandamme; J C Schmit; S Van Dooren; K Van Laethem; E Gobbers; W Kok; P Goubau; M Witvrouw; W Peetermans; E De Clercq; J Desmyter
Journal:  J Acquir Immune Defic Syndr Hum Retrovirol       Date:  1996-10-01

5.  Evaluation of a quality assurance program for quantitation of human immunodeficiency virus type 1 RNA in plasma by the AIDS Clinical Trials Group virology laboratories.

Authors:  B Yen-Lieberman; D Brambilla; B Jackson; J Bremer; R Coombs; M Cronin; S Herman; D Katzenstein; S Leung; H J Lin; P Palumbo; S Rasheed; J Todd; M Vahey; P Reichelderfer
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

6.  Absolute copy number and relative change in determinations of human immunodeficiency virus type 1 RNA in plasma: effect of an external standard on kit comparisons.

Authors:  D Brambilla; S Leung; J Lew; J Todd; S Herman; M Cronin; D E Shapiro; J Bremer; C Hanson; G V Hillyer; G D McSherry; R S Sperling; R W Coombs; P S Reichelderfer
Journal:  J Clin Microbiol       Date:  1998-01       Impact factor: 5.948

7.  Comparison of the Amplicor HIV-1 monitor test and the nucleic acid sequence-based amplification assay for quantitation of human immunodeficiency virus RNA in plasma, serum, and plasma subjected to freeze-thaw cycles.

Authors:  B P Griffith; M O Rigsby; R B Garner; M M Gordon; T M Chacko
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

8.  The relationship between serum human immunodeficiency virus type 1 (HIV-1) RNA level, CD4 lymphocyte percent, and long-term mortality risk in HIV-1-infected children. National Institute of Child Health and Human Development Intravenous Immunoglobulin Clinical Trial Study Group.

Authors:  L M Mofenson; J Korelitz; W A Meyer; J Bethel; K Rich; S Pahwa; J Moye; R Nugent; J Read
Journal:  J Infect Dis       Date:  1997-05       Impact factor: 5.226

9.  Multicenter evaluation of quantification methods for plasma human immunodeficiency virus type 1 RNA.

Authors:  H J Lin; L E Myers; B Yen-Lieberman; F B Hollinger; D Henrard; C J Hooper; R Kokka; S Kwok; S Rasheed; M Vahey
Journal:  J Infect Dis       Date:  1994-09       Impact factor: 5.226

  9 in total
  16 in total

1.  Obtaining unacceptable results in assays for quantitation of human immunodeficiency virus type 1 RNA in plasma samples.

Authors:  A Aguilera; A Vela; M Treviño; E Varela; R Seoane; B J Regueiro
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

2.  Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beacons.

Authors:  Jos J A M Weusten; Wim M Carpay; Tom A M Oosterlaken; Martien C A van Zuijlen; Paul A van de Wiel
Journal:  Nucleic Acids Res       Date:  2002-03-15       Impact factor: 16.971

3.  Multicenter evaluation of methods to quantitate human immunodeficiency virus type 1 RNA in seminal plasma.

Authors:  S A Fiscus; D Brambilla; R W Coombs; B Yen-Lieberman; J Bremer; A Kovacs; S Rasheed; M Vahey; T Schutzbank; P S Reichelderfer
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

4.  Assessment of agreement between the AMPLICOR HIV-1 MONITOR test versions 1.0 and 1.5.

Authors:  Charles E Hill; Alicia M Green; Jessica Ingersoll; Kirk A Easley; Frederick S Nolte; Angela M Caliendo
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

5.  Quantitation of human immunodeficiency virus type 1 RNA in different biological compartments.

Authors:  R N Shepard; J Schock; K Robertson; D C Shugars; J Dyer; P Vernazza; C Hall; M S Cohen; S A Fiscus
Journal:  J Clin Microbiol       Date:  2000-04       Impact factor: 5.948

6.  Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT.

Authors:  Priscilla Swanson; Carmen de Mendoza; Yagnya Joshi; Alan Golden; Richard L Hodinka; Vincent Soriano; Sushil G Devare; John Hackett
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

7.  Comparison of two amplification technologies for detection and quantitation of human immunodeficiency virus type 1 RNA in the female genital tract. Division of AIDS Treatment Research Initiative 009 Study Team.

Authors:  J Bremer; M Nowicki; S Beckner; D Brambilla; M Cronin; S Herman; A Kovacs; P Reichelderfer
Journal:  J Clin Microbiol       Date:  2000-07       Impact factor: 5.948

8.  Effects of anticoagulant, processing delay, and assay method (branched DNA versus reverse transcriptase PCR) on measurement of human immunodeficiency virus type 1 RNA levels in plasma.

Authors:  L M Kirstein; J W Mellors; C R Rinaldo; J B Margolick; J V Giorgi; J P Phair; E Dietz; P Gupta; C H Sherlock; R Hogg; J S Montaner; A Muñoz
Journal:  J Clin Microbiol       Date:  1999-08       Impact factor: 5.948

9.  Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  D G Murphy; L Côté; M Fauvel; P René; J Vincelette
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

10.  Evaluation of the abbott LCx HIV-1 RNA quantitative, a new assay for quantitative determination of human immunodeficiency virus type 1 RNA.

Authors:  N Zanchetta; G Nardi; L Tocalli; L Drago; C Bossi; F R Pulvirenti; C Galli; M R Gismondo
Journal:  J Clin Microbiol       Date:  2000-10       Impact factor: 5.948

View more