Literature DB >> 9886662

Effect of practical layered dielectric loads on SAR patterns from dual concentric conductor microstrip antennas.

F Rossetto1, P R Stauffer, V Manfrini, C J Diederich, G Biffi Gentili.   

Abstract

Radiation patterns of 2 and 4cm square Dual Concentric Conductor (DCC) microstrip antennas were studied theoretically with Finite Difference Time Domain (FDTD) analysis and compared with experimental measurements of power deposition (SAR) in layered lossy dielectric loads. Single and array configurations were investigated with 915 MHz excitation applied across either one, two or four sides, or four corners of the square apertures. FDTD simulations were carried out for realistic models of a muscle tissue load coupled to the DCC antennas with a 5 mm thick bolus of either distilled water or low loss Silicone Oil. This study characterizes the effect on SAR of adding three additional thin dielectric layers which are necessary for clinical use of the applicator. These layers consist of a 0.1 mm thick dielectric coating on the array surface to provide electrical isolation of DCC apertures, and 0.15 mm thick plastic layers above and below the bolus to contain the liquid. Experimental measurements of SAR in a plane 1 cm deep in muscle phantom agree well with theoretical FDTD simulations in the multi-layered tissue models. These studies reveal significant changes in SAR for applicator configurations involving low dielectric constant (Er) layers on either side of a high Er water bolus layer. Prominent changes include a broadening and centring of the SAR under each aperture as well as increased SAR penetration in muscle. No significant differences are noted between the simple and complete load configurations for the low Er Silicone Oil bolus. Both theoretical and measured data demonstrate relatively uniform SAR distributions with > 50% of maximum SAR extending to the perimeter of single and multi-aperture array configurations of DCC applicators when using a thin 5 mm water or Silicone Oil bolus.

Entities:  

Mesh:

Year:  1998        PMID: 9886662     DOI: 10.3109/02656739809018254

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  4 in total

1.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

Review 2.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

3.  Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Jaime L Schlorff; Yngve Birkelund; Svein Jacobsen; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2009-11       Impact factor: 3.914

4.  Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming.

Authors:  Paul R Stauffer; Paolo F Maccarini; Kavitha Arunachalam; Valeria De Luca; Sara Salahi; Alina Boico; Oystein Klemetsen; Yngve Birkelund; Svein K Jacobsen; Fernando Bardati; Piero Tognolatti; Brent Snow
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-22
  4 in total