Literature DB >> 9885606

Uniform fat suppression in hands and feet through the use of two-point Dixon chemical shift MR imaging.

M Maas1, P F Dijkstra, E M Akkerman.   

Abstract

PURPOSE: To assess the potential of two-point Dixon chemical shift magnetic resonance imaging to achieve uniform fat suppression in the distal parts of the extremities.
MATERIALS AND METHODS: Two-point Dixon chemical shift imaging was performed in 31 consecutive patients clinically suspected to have bone marrow disease. In some patients, Dixon studies were performed before and after the intravenous administration of gadopentetate dimeglumine, and in some patients follow-up examinations were performed, for a total of 64 studies. Areas of interest were the hand, wrist, foot, ankle, and lower leg. There was a special interest in the neuropathic foot and osteomyelitis. The uniformity of fat suppression in the entire field of view, the frequency of displacement artifacts, and the applicability of the technique in routine patient treatment were evaluated.
RESULTS: In 64 (100%) Dixon studies, uniform fat suppression was achieved. In 59 (92%) studies, there were no displacement artifacts. In five (8%) studies, displacement artifacts occurred; however, in only one (2%) study did they severely hamper the reading. Thus, in 63 (98%) studies, adequate diagnostic quality was obtained.
CONCLUSION: Two-point Dixon chemical shift imaging is a good technique for achieving uniform fat suppression in the distal parts of the extremities. Because the frequency of displacement artifacts is low, the technique is applicable in a routine clinical setting.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9885606     DOI: 10.1148/radiology.210.1.r99ja35189

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  MR-lymphangiography at 3.0 T--a feasibility study.

Authors:  Mike Notohamiprodjo; Ruediger G H Baumeister; Tobias F Jakobs; Kerstin U Bauner; Holger F Boehm; Annie Horng; Maximilian F Reiser; Christian Glaser; Karin A Herrmann
Journal:  Eur Radiol       Date:  2009-06-06       Impact factor: 5.315

Review 2.  The Dixon technique for MRI of the bone marrow.

Authors:  Niels van Vucht; Rodney Santiago; Bianca Lottmann; Ian Pressney; Dorothee Harder; Adnan Sheikh; Asif Saifuddin
Journal:  Skeletal Radiol       Date:  2019-07-15       Impact factor: 2.199

3.  3DMR osseous reconstructions of the shoulder using a gradient-echo based two-point Dixon reconstruction: a feasibility study.

Authors:  Soterios Gyftopoulos; Avner Yemin; Thomas Mulholland; Michael Bloom; Pippa Storey; Christian Geppert; Michael P Recht
Journal:  Skeletal Radiol       Date:  2012-07-25       Impact factor: 2.199

Review 4.  Evaluation of an imaging biomarker, Dixon quantitative chemical shift imaging, in Gaucher disease: lessons learned.

Authors:  L van Dussen; E M Akkerman; C E M Hollak; A J Nederveen; M Maas
Journal:  J Inherit Metab Dis       Date:  2014-06-13       Impact factor: 4.982

5.  Fracture of ankle: MRI using opposed-phase imaging obtained from turbo spin echo modified Dixon image shows improved sensitivity.

Authors:  Jin Hee You; In Hwan Kim; Jinwoo Hwang; Hye Sun Lee; Eun Hae Park
Journal:  Br J Radiol       Date:  2018-06-05       Impact factor: 3.039

6.  Systematic assessment of the growth plates of the wrist in young gymnasts: development and validation of the Amsterdam MRI assessment of the Physis (AMPHYS) protocol.

Authors:  Laura S Kox; Rik B J Kraan; Kees F van Dijke; Robert Hemke; Sjoerd Jens; Milko C de Jonge; Edwin H G Oei; Frank F Smithuis; Maaike P Terra; Mario Maas
Journal:  BMJ Open Sport Exerc Med       Date:  2018-04-09

7.  Role of intrinsic muscle atrophy in the etiology of claw toe deformity in diabetic neuropathy may not be as straightforward as widely believed.

Authors:  Sicco A Bus; Mario Maas; Robert P J Michels; Marcel Levi
Journal:  Diabetes Care       Date:  2009-03-11       Impact factor: 19.112

Review 8.  Clinical applications of advanced magnetic resonance imaging techniques for arthritis evaluation.

Authors:  Teodoro Martín Noguerol; Antonio Luna; Marta Gómez Cabrera; Alexie D Riofrio
Journal:  World J Orthop       Date:  2017-09-18

9.  Usefulness of black boundary artifact on opposed-phase imaging from turbo spin-echo two-point mDixon MRI for delineation of an arthroscopically confirmed small fracture of the lateral talar dome: A case report.

Authors:  Eun Hae Park; Kwang-Bok Lee
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.889

  9 in total