Literature DB >> 9873993

Evaluation of the affinity measurement of anti-HIV-1 p17 monoclonal antibody by BIAcore.

A Ota1, S Ueda.   

Abstract

The methods of measuring the affinity constants of anti-HIV-1 p17 monoclonal antibodies (MAbs) using the double antibody methods in the liquid phase and the biomolecular interaction analysis by BIAcore system (Pharmacia Biosensor AB, Uppsala, Sweden) were compared. MAbs, HyHIV1-6, recognizing residues 12-29 (P12-29) of p17 and the naive protein, p17, were used. The kinetic association constants (KAs) obtained using the double antibody method were 2.40 x 10(7) - 1.40 x 10(8)M(-1) for P12-29, and 4.80 x 106 - 1.80 x 10(7) M(-1) for p17. In the BIAcore system where P12-29 or p17 was used as immobilized antigens onto the sensorchip, the KAs were 1.57 x 10(9) - 4.81 x 10(9) M(-1) for P12-29, and 1.52 x 10(9) - 1.21 x 10(10) M(-1) for p17. On the other hand, when MAbs were immobilized onto the sensorchip and P12-29 or rp17 was used as analyte, the KAs for P12-29 and p17 were in the region 3 x10(8) - 3 x 10(9), 1 x 10(8) - 3 x 10(9) M(-1), respectively. These data show that the KAs were higher than those obtained using the double antibody method, however, no significant difference could be observed. Moreover, the KAs obtained for p17 using MAbs as ligand were similar for BIAcore and the double antibody method except for HyHIV2. Therefore, the BIAcore system can be used for the affinity measurement instead of the double antibody method.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9873993     DOI: 10.1089/hyb.1998.17.471

Source DB:  PubMed          Journal:  Hybridoma        ISSN: 0272-457X


  4 in total

1.  Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies.

Authors:  Ryan J White; Hannah M Kallewaard; Wen Hsieh; Adriana S Patterson; Jesse B Kasehagen; Kevin J Cash; Takanori Uzawa; H Tom Soh; Kevin W Plaxco
Journal:  Anal Chem       Date:  2012-01-03       Impact factor: 6.986

2.  Peptide beacons: a new design for polypeptide-based optical biosensors.

Authors:  Kenneth J Oh; Kevin J Cash; Verena Hugenberg; Kevin W Plaxco
Journal:  Bioconjug Chem       Date:  2007-04-27       Impact factor: 4.774

3.  Chimeric peptide beacons: a direct polypeptide analog of DNA molecular beacons.

Authors:  Kenneth J Oh; Kevin J Cash; Arica A Lubin; Kevin W Plaxco
Journal:  Chem Commun (Camb)       Date:  2007-12-14       Impact factor: 6.222

4.  In Vitro and In Vivo studies of monoclonal antibodies with prominent bactericidal activity against Burkholderia pseudomallei and Burkholderia mallei.

Authors:  Shimin Zhang; Shaw-Huey Feng; Bingjie Li; Hyung-Yong Kim; Joe Rodriguez; Shien Tsai; Shyh-Ching Lo
Journal:  Clin Vaccine Immunol       Date:  2011-03-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.