Literature DB >> 9871866

Descriptive information of topographic parameters computed at the optic nerve head with the Heidelberg retina tomograph.

A Saruhan1, S Orgül, I Koçak, C Prünte, J Flammer.   

Abstract

PURPOSE: To analyze the frequency distribution and descriptive information of topometric data obtained with the Heidelberg Retina Tomograph (HRT) in a normal population.
METHODS: Topographic measurements of the optic disc were acquired and evaluated using the HRT in 225 subjects between 12 and 90 years of age. After randomly selecting one eye per subject, the frequency distributions, mean values, minima, maxima, and first, fifth, fiftieth, ninety-fifth, and ninety-ninth percentiles were evaluated for topographic parameters computed by the HRT. The influence of age, intraocular pressure (IOP), disc size, and disc shape on optic disc topometric data was analyzed. A principal component analysis of the topometric parameters was performed. The frequency distributions, mean values, minima, maxima, and first, fifth, fiftieth, ninety-fifth, and ninety-ninth percentiles of the interocular difference in topographic parameters were evaluated.
RESULTS: All topographic parameters showed a unimodal but not necessarily normal distribution. None of the parameters showed a relevant correlation with age, IOP (in the normal range), and overall shape of the anterior optic nerve, but a few parameters showed a clinically significant correlation with disc size. A principal component analysis identified four relevant factors (optic nerve cup, retinal nerve fiber layer, optic disc size, and optic nerve cup shape) in the entire data set of optic nerve topometric data. The absolute value of all interocular differences in topographic parameters showed an asymmetric but unimodal distribution.
CONCLUSION: The mathematical description of the optic nerve cup shape provides information on optic nerve head topography independently from cupping, nerve fiber layer thickness, and disc size. Potentially, quantification of further aspects in optic nerve head topography might improve the discriminatory power of computerized quantitative optic nerve head analysis.

Mesh:

Year:  1998        PMID: 9871866

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  8 in total

1.  Evaluation and definition of physiologic macro cups with confocal optic nerve analysis (HRT).

Authors:  E Arenas-Archila; F Caycedo-Yunis; M R Rodríguez
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Topographic characteristics of the optic nerve head measured with scanning laser tomography in normal Japanese subjects.

Authors:  Hideya Uchida; Tetsuya Yamamoto; Makoto Araie; Goji Tomita; Motohiro Shirakashi; Keiji Yoshikawa
Journal:  Jpn J Ophthalmol       Date:  2005 Nov-Dec       Impact factor: 2.447

3.  Detecting glaucoma with RADAAR: the Bridlington Eye Assessment Project.

Authors:  M J Hawker; S A Vernon; C L Tattersall; H S Dua
Journal:  Br J Ophthalmol       Date:  2006-06       Impact factor: 4.638

4.  Large optic nerve heads: megalopapilla or megalodiscs.

Authors:  R Sampaolesi; J R Sampaolesi
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

5.  Optic disc topographic parameters measured in the normal cynomolgus monkey by confocal scanning laser tomography.

Authors:  T Taniguchi; M Shimazawa; M Araie; G Tomita; M Sasaoka; Y Kitazawa; H Hara
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

6.  [Screening for diabetic retinopathy and optic disc topography with the "retinal thickness analyzer" (RTA)].

Authors:  A S Neubauer; C Chryssafis; M Thiel; S Priglinger; U Welge-Lüssen; A Kampik
Journal:  Ophthalmologe       Date:  2005-03       Impact factor: 1.059

7.  Differential effects of tamoxifen and anastrozole on optic cup size in breast cancer survivors.

Authors:  Alvin Eisner; Maureen D Toomey; Julie Falardeau; John R Samples; John T Vetto
Journal:  Breast Cancer Res Treat       Date:  2007-01-27       Impact factor: 4.872

8.  Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes.

Authors:  Christopher Bowd; Linda M Zangwill; Felipe A Medeiros; Jiucang Hao; Kwokleung Chan; Te-Won Lee; Terrence J Sejnowski; Michael H Goldbaum; Pamela A Sample; Jonathan G Crowston; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-07       Impact factor: 4.799

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.