Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes.

W M Grill1, J T Mortimer.   

Abstract

The objective of this investigation was to measure the input-output (I-O) properties of chronically implanted nerve cuff electrodes. Silicone rubber spiral nerve cuff electrodes, containing 12 individual platinum electrode contacts, were implanted on the sciatic nerve of seven adult cats for 28-34 weeks. Measurements of the torque generated at the ankle joint by electrical stimulation of the sciatic nerve were made every 1-2 weeks for the first 6 weeks post-implant and every 3-5 weeks between 6 weeks and 32 weeks post-implant. In three implants the percutaneous lead cable was irreparably damaged by the animal within 4 weeks after implant and further testing was not possible. One additional lead cable was irreparably damaged by the animal at 17 weeks post-implant. The three remaining implants functioned for 28, 31, and 32 weeks. Input-output curves of ankle joint torque as a function of stimulus current amplitude were repeatable within an experimental session, but there were changes in I-O curves between sessions. The degree of variability in I-O properties differed between implants and between different contacts within the same implant. After 8 weeks, the session to session changes in the stimulus amplitude required to generate 50% of the maximum torque (I50) were smaller (15+/-19%, mean +/- s.d.) than the changes in I50 measured between 1 week and 8 weeks post-implant (34+/-42%). Furthermore, the I-O properties were more stable across changes in limb position in the late post-implant period than in acutely implanted cuff electrodes. These results suggest that tissue encapsulation acted to stabilize chronically implanted cuff electrodes. Electrode movement relative to the nerve, de- and regeneration of nerve fibers, and the inability to precisely reproduce limb position in the measurement apparatus all may have contributed to the variability in I-O properties.

Entities:  

Mesh:

Year:  1998        PMID: 9865883     DOI: 10.1109/86.736150

Source DB:  PubMed          Journal:  IEEE Trans Rehabil Eng        ISSN: 1063-6528


  31 in total

1.  Behavioral modulation of tactile responses in the rat somatosensory system.

Authors:  E E Fanselow; M A Nicolelis
Journal:  J Neurosci       Date:  1999-09-01       Impact factor: 6.167

2.  Two-way communication for programming and measurement in a miniature implantable stimulator.

Authors:  M A Thil; B Gérard; J C Jarvis; J Delbeke
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

3.  Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia.

Authors:  William D Memberg; Katharine H Polasek; Ronald L Hart; Anne M Bryden; Kevin L Kilgore; Gregory A Nemunaitis; Harry A Hoyen; Michael W Keith; Robert F Kirsch
Journal:  Arch Phys Med Rehabil       Date:  2014-02-20       Impact factor: 3.966

4.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

5.  Sciatic nerve stimulation and its effects on upper airway resistance in the anesthetized rabbit model relevant to sleep apnea.

Authors:  Matthew Schiefer; Jenniffer Gamble; Kingman P Strohl
Journal:  J Appl Physiol (1985)       Date:  2018-06-07

6.  Alteration of neural action potential patterns by axonal stimulation: the importance of stimulus location.

Authors:  Patrick E Crago; Nathaniel S Makowski
Journal:  J Neural Eng       Date:  2014-08-27       Impact factor: 5.379

7.  Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity.

Authors:  Katharine H Polasek; Harry A Hoyen; Michael W Keith; Robert F Kirsch; Dustin J Tyler
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-09-22       Impact factor: 3.802

8.  Standing after spinal cord injury with four-contact nerve-cuff electrodes for quadriceps stimulation.

Authors:  Lee E Fisher; Michael E Miller; Stephanie N Bailey; John A Davis; James S Anderson; Lori Rhode; Dustin J Tyler; Ronald J Triolo
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-10       Impact factor: 3.802

9.  Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve.

Authors:  L E Fisher; D J Tyler; J S Anderson; R J Triolo
Journal:  J Neural Eng       Date:  2009-07-15       Impact factor: 5.379

Review 10.  Spinal cord injury: present and future therapeutic devices and prostheses.

Authors:  Simon F Giszter
Journal:  Neurotherapeutics       Date:  2008-01       Impact factor: 7.620

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.