Literature DB >> 9860203

Can visual assessment of flow waveform morphology detect anastomotic error in off-pump coronary artery bypass grafting?

S F Jaber1, S C Koenig, B BhaskerRao, D J VanHimbergen, P A Spence.   

Abstract

OBJECTIVE: Flow probes are being used for intraoperative assessment of anastomotic quality during off-pump coronary artery bypass grafting (CABG). We conducted a survey with the cooperation of 19 international surgeons to assess the ability of surgeons to detect anastomotic errors by evaluating mean flow and flow waveform morphology.
MATERIAL AND METHODS: Mongrel dogs underwent mammary to left anterior descending (LAD) grafting. Mean graft flow and flow wave morphology for varying degrees of anastomotic stenoses were recorded using transit-time flow probes. A questionnaire consisting of ten different recorded flow tracings and the corresponding mean flows were given to 20 surgeons from around the world. The surgeons were asked to determine the degree of stenosis and whether they would re-do the anastomosis based upon the mean flow and the flow tracings.
RESULTS: All of the 19 surgeons that responded were able to clearly identify a highly stenotic graft (>90% stenosis). However, 24% would re-do a fully patent anastomosis, 58% accepted an anastomosis with moderate stenosis, and 72% accepted anastomoses with severe stenosis.
CONCLUSIONS: Evaluation of flow tracing morphology and/or mean flows can be used to reliably detect nearly occluded anastomoses (>90% stenosis). However, surgeons should be cautious in assessing anastomoses with lesser degrees of stenosis, as they may be more difficult to reliably interpret.

Entities:  

Mesh:

Year:  1998        PMID: 9860203     DOI: 10.1016/s1010-7940(98)00232-2

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Intraoperative assessment and quantification of coronary artery graft patency performed on or off cardiopulmonary bypass.

Authors:  Eric D Rauch; Christopher Leach; Terry Barnes; Kurt Driscoll; Kurt Strutz; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-06

2.  Understanding coronary artery bypass transit time flow curves: role of bypass graft compliance.

Authors:  Matija Jelenc; Blaž Jelenc; Tomislav Klokočovnik; Nikola Lakič; Borut Geršak; Ivan Kneževic
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-10-30

3.  A new way to use transit-time flow measurement for coronary artery bypass grafting.

Authors:  Lukas Stastny; Markus Kofler; Vitalijs Zujs; Elfriede Ruttmann; Julia Dumfarth; Juliane Kilo; Alexandra Brix; Simone Gasser; Adel Sakic; Thomas Schachner; Michael Grimm; Nikolaos Bonaros
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10