Blood volume measurement at the bedside using ICG pulse spectrophotometry.

M Haruna1, K Kumon, N Yahagi, Y Watanabe, Y Ishida, N Kobayashi, T Aoyagi.   

Abstract

BACKGROUND: In the treatment of critically ill patients, blood volume (BV) measurement requires injection of some tracer substance and subsequent blood sampling to analyze the tracer concentration. To obviate both the sampling and laboratory analysis, techniques of pulse oximetry have been adapted to the noninvasive optical measurement in the patient's nose or finger of the arterial concentration of an injectable dye.
METHODS: The authors report the clinical accuracy of a new noninvasive bedside BV measurement test that uses pulse spectrophotometry (the pulse method). The device detects pulsatile changes of tissue optical density of a nostril or a finger spanned by a probe emitting two infrared wavelengths (805 and 890 nm). After a peripheral or central intravenous injection of indocyanine green, the arterial dye concentration is continuously computed by reference to the previously measured blood hemoglobin concentration. Three types of tests of its accuracy are described here.
RESULTS: In 10 healthy volunteers, the authors compared BV determined by the pulse method with an (131)I-labeled human serum albumin method. Three subject data sets were excluded because of motion artifact, a low signal:noise ratio, or both. For the other seven volunteers, the bias+/-SD of pulse spectrophotometric BV values were 0.20+/-0.24 l (or 4.2+/-4.9%) for the nose probe and 0.34+/-0.31 l (or 7.3+/-6.9%) for the finger probe, with a mean BV of 5 l. In 30 patients who underwent cardiac surgery, the pulse method was compared with a standard indocyanine green method using intermittent blood sampling. In three patients, the BV could not be determined by the pulse method because of motion artifact, low signal:noise ratio, or both. In 27 patients, the bias+/-SD of the BV by the pulse method was -0.23+/-0.37 l (-5.3+/-8.7%) for the nose and -0.25+/-0.5 l (-4.2+/-8.4%) for the finger. Patient BV ranged from 2.51 to 7.13 l (mean, 4.48 l). In 10 additional patients before cardiac surgery, BV was measured by the pulse method before and shortly after removal of 400 ml blood. The pulse method recorded a decrease of BV of 480+/-114 mL Three days after venesection, the mean BV was 117+/-159 ml less than the predonation control.
CONCLUSIONS: In most patients, the pulse method provides bedside measurement of BV without blood sampling (except for hemoglobin determination), with an estimated error less than 10%. In 10-30% of tests the method failed because of motion distortion of the record during the 10-min data collection period or because of insufficient pulse amplitude in the test tissue.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9856705     DOI: 10.1097/00000542-199812000-00008

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  18 in total

1.  Monitoring techniques for blood volume in the anethesia and intensive care setting.

Authors:  B Allaria; M Favaro; M Resta
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

2.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

3.  Indocyanine green-enhanced imaging of antigen-induced arthritis with an integrated optical imaging/radiography system.

Authors:  Reinhard Meier; Christian Krug; Daniel Golovko; Sophie Boddington; Guido Piontek; Martina Rudelius; Elizabeth J Sutton; Andrea Baur-Melnyk; Ella F Jones; Heike E Daldrup-Link
Journal:  Arthritis Rheum       Date:  2010-08

4.  Neurotoxic effects of indocyanine green -cerebellar granule cell culture viability study.

Authors:  Beata Toczylowska; Elzbieta Zieminska; Grazyna Goch; Daniel Milej; Anna Gerega; Adam Liebert
Journal:  Biomed Opt Express       Date:  2014-02-19       Impact factor: 3.732

5.  Determination of the standard value of circulating blood volume during anesthesia using pulse dye-densitometry: a multicenter study in Japan.

Authors:  Takehiko Iijima; Hiroshi Ueyama; Yoshiyuki Oi; Isao Fukuda; Hironori Ishihara; Hikaru Kohase; Yoshifumi Kotake; Kaoru Koyama; Hideki Miyao; Naoki Kobayashi
Journal:  J Anesth       Date:  2005       Impact factor: 2.078

Review 6.  Complexity of blood volume control system and its implications in perioperative fluid management.

Authors:  Takehiko Iijima
Journal:  J Anesth       Date:  2009-11-18       Impact factor: 2.078

7.  Stability of cirrhotic systemic hemodynamics ensures sufficient splanchnic blood flow after living-donor liver transplantation in adult recipients with liver cirrhosis.

Authors:  Tomohide Hori; Shintaro Yagi; Taku Iida; Kentaro Taniguchi; Kentaro Yamagiwa; Chiduru Yamamoto; Takashi Hasegawa; Koichiro Yamakado; Takuma Kato; Kanako Saito; Linan Wang; Mie Torii; Yukinobu Hori; Kan Takeda; Kazuo Maruyama; Shinji Uemoto
Journal:  World J Gastroenterol       Date:  2007-11-28       Impact factor: 5.742

8.  Design of liver functional reserve monitor based on three-wavelength from red light to IR.

Authors:  Fuli Ye; Huimiao Zhan; Guilian Shi
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285

Review 9.  Systemic hemodynamics in advanced cirrhosis: Concerns during perioperative period of liver transplantation.

Authors:  Tomohide Hori; Yasuhiro Ogura; Yasuharu Onishi; Hideya Kamei; Nobuhiko Kurata; Motoshi Kainuma; Hideo Takahashi; Shogo Suzuki; Takashi Ichikawa; Shoko Mizuno; Tadashi Aoyama; Yuki Ishida; Takahiro Hirai; Tomoko Hayashi; Kazuko Hasegawa; Hiromu Takeichi; Atsunobu Ota; Yasuhiro Kodera; Hiroyuki Sugimoto; Taku Iida; Shintaro Yagi; Kentaro Taniguchi; Shinji Uemoto
Journal:  World J Hepatol       Date:  2016-09-08

10.  Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration.

Authors:  Menno R Germans; Philip C de Witt Hamer; Leonard J van Boven; Koos A H Zwinderman; Gerrit J Bouma
Journal:  Acta Neurochir (Wien)       Date:  2009-09-04       Impact factor: 2.216