Literature DB >> 9855157

Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients.

M G dos Santos1, S Makk, A Berghold, M Eckhardt, A Haas.   

Abstract

OBJECTIVE: To analyze the increase in intraocular pressure (IOP) caused by anatomic and physiologic factors in overweight patients when using Goldmann applanation tonometry.
DESIGN: A prospective cohort study. PARTICIPANTS: Seventy average-weight individuals who had no difficulties with IOP measurements at the slit lamp and 12 obese patients with suspected glaucoma who could position the head at the slit lamp only with great effort participated. INTERVENTION: The authors compared IOP values between slit-lamp-mounted Goldmann applanation tonometry and Perkins hand-held tonometry. MAIN OUTCOME MEASURE: The difference in Goldmann and Perkins IOP measurements was examined.
RESULTS: In the group of obese patients, the mean IOP was 20.9+/-2.28 mmHg (mean +/- standard deviation; range, 18-26 mmHg) for the right eye and 21.4+/-3.16 mmHg (range, 16-28 mmHg) for the left eye when determined by Goldmann tonometry and 16.3+/-2.39 mmHg (range, 13-20 mmHg) for the right eye and 16.3+/-2.42 (range, 11-19 mmHg) for the left eye when determined by Perkins tonometry. The mean decrease was 4.5+/-1.3 mmHg (range, 3-7 mmHg) for the right eye and 4.9+/-1.9 mmHg (range, 2-9 mmHg) for the left eye. In the control group, the mean difference between the two types of tonometers for the right eye was 0.34+/-0.69 mmHg and for the left eye was 0.33+/-0.82 mmHg. Patients who had a falsely elevated IOP on Goldmann tonometry had an average body mass index of 34+/-3.82 (range, 28.5-41.9); most were female (5:1 ratio).
CONCLUSION: The authors believe simultaneous breath-holding and thorax compression, with subsequent increase in venous pressure, may be a causative factor for transitory elevations of IOP. Perkins tonometry in obese patients may help avoid a false diagnosis of glaucoma caused by transitory elevations in IOP.

Entities:  

Mesh:

Year:  1998        PMID: 9855157     DOI: 10.1016/S0161-6420(98)91226-X

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  17 in total

Review 1.  [Sources of error in Goldmann applanation tonometry].

Authors:  F Rüfer
Journal:  Ophthalmologe       Date:  2011-06       Impact factor: 1.059

2.  Clinical comparison of Pulsair non-contact tonometer and Goldmann applanation tonometer in Indian population.

Authors:  Shalini Mohan; Satyaprakash Tiwari; Arvind Jain; Jaya Gupta; Surendra Kumar Sachan
Journal:  J Optom       Date:  2013-07-26

3.  [Glaucoma and ocular hypertension in primary care].

Authors:  J Jaén Díaz; I Sanz Alcolea; F López De Castro; T Pérez Martínez; P Ortega Campos; R Corral Morales
Journal:  Aten Primaria       Date:  2001-06-15       Impact factor: 1.137

4.  High intraocular pressure is associated with cardiometabolic risk factors in South Korean men: Korean National Health and Nutrition Examination Survey, 2008-2010.

Authors:  Y-H Kim; S W Jung; G-E Nam; K Do Han; A R Bok; S J Baek; K-H Cho; Y S Choi; S-M Kim; S-Y Ju; D-H Kim
Journal:  Eye (Lond)       Date:  2014-03-07       Impact factor: 3.775

5.  Association of Metabolic Syndrome With Glaucoma and Ocular Hypertension in a Midwest United States Population.

Authors:  Kristi Y Wu; David O Hodge; Launia J White; Jacinta McDonald; Gavin W Roddy
Journal:  J Glaucoma       Date:  2021-12-02       Impact factor: 2.290

6.  Insulin resistance is associated with intraocular pressure elevation in a non-obese Korean population.

Authors:  Yoon Hong Chun; Kyungdo Han; Shin Hae Park; Kyung-Min Park; Hyeon Woo Yim; Won-Chul Lee; Yong Gyu Park; Yong-Moon Park
Journal:  PLoS One       Date:  2015-01-05       Impact factor: 3.240

Review 7.  The Association between Adiposity and the Risk of Glaucoma: A Meta-Analysis.

Authors:  Weiming Liu; Jiawen Ling; Yiyi Chen; Yan Wu; Peirong Lu
Journal:  J Ophthalmol       Date:  2017-06-12       Impact factor: 1.909

8.  Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods.

Authors:  R Arora; H Bellamy; Mw Austin
Journal:  Clin Ophthalmol       Date:  2014-03-26

9.  The Association Between Primary Open Angle Glaucoma and Clustered Components of Metabolic Syndrome.

Authors:  Seyed Ahmad Rasoulinejad; Ali Kasiri; Mahdi Montazeri; Negin Rashidi; Maryam Montazeri; Mohammad Montazeri; Hesam Hedayati
Journal:  Open Ophthalmol J       Date:  2015-10-06

10.  Associations with intraocular pressure across Europe: The European Eye Epidemiology (E3) Consortium.

Authors:  Anthony P Khawaja; Henriët Springelkamp; Catherine Creuzot-Garcher; Cécile Delcourt; Albert Hofman; René Höhn; Adriana I Iglesias; Roger C W Wolfs; Jean-François Korobelnik; Rufino Silva; Fotis Topouzis; Katie M Williams; Alain M Bron; Gabriëlle H S Buitendijk; Maria da Luz Cachulo; Audrey Cougnard-Grégoire; Jean-François Dartigues; Christopher J Hammond; Norbert Pfeiffer; Angeliki Salonikiou; Cornelia M van Duijn; Johannes R Vingerling; Robert N Luben; Alireza Mirshahi; Julia Lamparter; Caroline C W Klaver; Nomdo M Jansonius; Paul J Foster
Journal:  Eur J Epidemiol       Date:  2016-09-09       Impact factor: 8.082

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.