Literature DB >> 985066

Vascular complications of intra-aortic balloon pumping.

J Alpert, E K Bhaktan, I Gielchinsky, L Gilbert, B J Brener, D K Brief, V Parsonnet.   

Abstract

Vascular injury or occlusion from intra-aortic balloon pumping (IABP) that results in actual or potential limb ischemia occurs more frequently than reported. In a series of 79 IABP patients, 36 lived long enough to have the balloon catheter removed; thirteen (36%) of them had vascular complications. The complications were in three patients with an injury at the insertion site, eight patients with arterial thromboses, and two with arterial occlusion by the large balloon catheter. Local artery revision, thrombectomy alone, or thrombectomy with femorofemoral cross-over grafting was required in 11 patients. Femorofemoral crossover graft was utilized when arterial occlusion would have ordinarily required premature balloon removal or when immediate arterial occlusion by the catheter was recognized at the time of balloon insertion. This was preferable to transferring, replacing, or discontinuing IABP, since the same factors that led to thrombosis in the first place would have eventually come into play again. Patients should be observed frequently and have Doppler limb pulse determinations every four hours to avoid ischemic catastrophies. Proper IABP weaning and the use of a Fogarty catheter at the time of balloon removal is mandatory to prevent complications. Femorofemoral crossover graft is indicated for ischemic limbs when IABP must be continued.

Entities:  

Mesh:

Year:  1976        PMID: 985066     DOI: 10.1001/archsurg.1976.01360290024004

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  5 in total

1.  Cerebral air embolism secondary to intra-aortic balloon pump rupture.

Authors:  Salvador Cruz-Flores; Alan L Diamond; Enrique C Leira
Journal:  Neurocrit Care       Date:  2005       Impact factor: 3.210

2.  Experience with intra-aortic balloon pumping and the first clinical application of an ellipsoid left ventricular assist device: invited commentary.

Authors:  D Bregman
Journal:  World J Surg       Date:  1978-11       Impact factor: 3.352

3.  Intra-aortic balloon pump: a perspective.

Authors:  J E McGee
Journal:  J Natl Med Assoc       Date:  1981-09       Impact factor: 1.798

4.  Vascular complications associated with the use of intraaortic balloon pumping.

Authors:  P M Sanfelippo; N H Baker; H G Ewy; P J Moore; J W Thomas; G J Brahos; R F McVicker
Journal:  Tex Heart Inst J       Date:  1987-06

5.  Limb salvage following iatrogenic arterial injury: complications of cardiac support using intra-aortic balloon pumps.

Authors:  Adam Hunt; Owen Waldin; Hani Slim; Ranjeet Brar
Journal:  BMJ Case Rep       Date:  2016-06-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.