Limb salvage following iatrogenic arterial injury: complications of cardiac support using intra-aortic balloon pumps.

Adam Hunt1, Owen Waldin1, Hani Slim1, Ranjeet Brar1.   

Abstract

This is a unique case report describing complex limb salvage in a patient who experienced acute limb ischaemia due to a complication of intra-aortic balloon pump (IABP) counterpulsation. This case focuses on a patient who had an IABP counterpulsation device inserted following myocardial infarction, requiring urgent coronary artery bypass grafting for acute coronary syndrome. Postoperatively, the IABP could not be removed, with consequent iliac thrombosis and acute limb ischaemia. Emergency femoral-to-femoral crossover bypass was performed using a polytetrafluoroethylene graft. A portion of the IABP balloon tip was entrapped and retained, however, and became the focus of delayed septicaemia, resulting in graft infection and wound breakdown 6 weeks later. Explantation of the residual balloon tip, ligation of the right external iliac artery and redo femoral-femoral crossover using the great saphenous vein were successfully performed. 2016 BMJ Publishing Group Ltd.

Entities:  

Mesh:

Year:  2016        PMID: 27268290      PMCID: PMC4904379          DOI: 10.1136/bcr-2016-215167

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  42 in total

1.  Entrapping of the clotted intra-aortic balloon in the descending aorta.

Authors:  H Shafei; G Webb; S C Lennox
Journal:  Eur J Cardiothorac Surg       Date:  1991       Impact factor: 4.191

2.  Vascular complications related to intraaortic balloon counterpulsation: an analysis of ten years experience.

Authors:  T Busch; H Sîrbu; D Zenker; H Dalichau
Journal:  Thorac Cardiovasc Surg       Date:  1997-04       Impact factor: 1.827

3.  The entrapped balloon: report of a possibly serious complication.

Authors:  G M Aru; J T King; H Hovaguimian; H S Floten; A Ahmad; A Starr
Journal:  J Thorac Cardiovasc Surg       Date:  1986-01       Impact factor: 5.209

4.  Ischaemic complications with intra-aortic balloon counter-pulsation: incidence and management.

Authors:  H Sirbu; T Busch; I Aleksic; M Friedrich; H Dalichau
Journal:  Cardiovasc Surg       Date:  2000-01

5.  Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases.

Authors:  Zile Singh Meharwal; Naresh Trehan
Journal:  Eur J Cardiothorac Surg       Date:  2002-04       Impact factor: 4.191

6.  Vascular complications as a result of intra-aortic balloon pumping.

Authors:  D J Sutorius; J A Majeski; S F Miller
Journal:  Am Surg       Date:  1979-08       Impact factor: 0.688

7.  [A case of emergency operation of entrapped intra-aortic balloon].

Authors:  Y Nakayama; K Naito; M Sakai; M Natsuaki; T Itoh
Journal:  Kyobu Geka       Date:  1992-09

8.  Intraaortic balloon pump entrapment.

Authors:  F H Millham; H M Hudson; J Woodson; J O Menzoian
Journal:  Ann Vasc Surg       Date:  1991-07       Impact factor: 1.466

9.  Total aortic occlusion caused by sustained balloon inflation: a previously unreported complication of intraaortic balloon counterpulsation.

Authors:  M A Ferrell; M Doherty; R M Zusman; I S Nash
Journal:  Cathet Cardiovasc Diagn       Date:  1993-11

Review 10.  Retained intraaortic balloon. Case report and review of the literature.

Authors:  A M Grande; L Martinelli; A Graffigna; M Viganò
Journal:  Tex Heart Inst J       Date:  1995