Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings.

D Zweers1, J Geleijns, N J Aarts, L J Hardam, J S Laméris, F W Schultz, L J Schultze Kool.   

Abstract

Fluoroscopy guided interventions, such as transjugular intrahepatic portosystemic shunt (TIPS) procedures, can results in relatively high radiation doses to patients and staff. The purpose of this study was to evaluate the possible benefit of dedicated fluoroscopy exposure factors in the reduction of doses. Doses to patients and staff were measured during fluoroscopy-guided TIPS procedures in two Dutch university hospitals. Patient doses were calculated from dose-area product (DAP) measurements, entrance beam dimensions and DAP conversion factors. Staff doses were measured outside lead aprons using electronic personal dosemeters. Average patient entrance skin dose (ESD) rate during fluoroscopy was 49 mGy min-1 (13 cases, average fluoroscopy duration 32 min) in one hospital, and 6 mGy min-1 (10 cases, average fluoroscopy duration 50 min) in the other. Estimated staff effective dose per procedure was 28 microSv average in the first hospital compared with 4 microSv average in the other. The use of dedicated fluoroscopy exposure factors, with a relatively high tube voltage and lower tube current resulted in a significant dose reduction for patient and staff in this type of radiological intervention.

Entities:  

Mesh:

Year:  1998        PMID: 9849393     DOI: 10.1259/bjr.71.846.9849393

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Radiation dose of digital vs conventional fluororadiography of the upper GI tract.

Authors:  G Pärtan; R Mayrhofer; H Mosser; T Mahdi; W Hruby
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

2.  Radiation dose in vertebroplasty.

Authors:  A Mehdizade; K O Lovblad; K E Wilhelm; T Somon; S G Wetzel; A D Kelekis; H Yilmaz; G Abdo; J B Martin; J M Viera; D A Rüfenacht
Journal:  Neuroradiology       Date:  2004-02-14       Impact factor: 2.804

3.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 4.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

5.  Interventional Angiography: Radiation Protection for the Examiner by using Lead-free Gloves.

Authors:  Peter Kamusella; Fabian Scheer; Christopher Wilhelm Lüdtke; Philipp Wiggermann; Christian Wissgott; Reimer Andresen
Journal:  J Clin Diagn Res       Date:  2017-07-01

6.  Radiation doses to operators performing transjugular intrahepatic portosystemic shunt using a flat-panel detector-based system and ultrasound guidance for portal vein targeting.

Authors:  Roberto Miraglia; Roberta Gerasia; Luigi Maruzzelli; Mario D'Amico; Angelo Luca
Journal:  Eur Radiol       Date:  2016-08-25       Impact factor: 5.315

7.  Technical note: Reduction of radiation dose using ultrasound guidance during transjugular intrahepatic portosystemic shunt procedure.

Authors:  Roshan S Livingstone; Shyamkumar N Keshava
Journal:  Indian J Radiol Imaging       Date:  2011-01

8.  Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals.

Authors:  Nnamdi Norbert Jibiri; Tawakalitu Oluwatoyin Akintunde; Musa Yusuf Dambele; Christopher Jimoh Olowookere
Journal:  Mol Imaging Radionucl Ther       Date:  2016-10-05