Literature DB >> 9840895

Reliability of spectral EMG parameters of healthy back extensors during submaximum isometric fatiguing contractions and recovery.

J P Peach1, J Gunning, S M McGill.   

Abstract

Spectral EMG parameters are being used as an objective evaluation of low back rehabilitation programs. The reliability of these spectral parameters is important in determining the validity of this evaluation tool. Two groups of eight subjects, with no history of back pain, were measured: the first group every day for one week; the second group one day per week for four weeks. During each session, subjects performed a 30-second isometric fatiguing contraction of the back extensors at 60% MVC followed by a 60-second rest and a 10-second repeat contraction. The intraclass correlation coefficient (ICC) did not demonstrate high reliability (ICC < 0.6) for the rate of median power frequency (MedPF) change (Hz/s), the magnitude of the recovery (Hz) and differences between the dominant and the non-dominant sides within a subject. However, the initial MedPF (Hz) of the fatigue and repeat contractions demonstrated excellent reliability (ICC > 0.8) with five or more repeated measures. The practical implication of this work is that the experimental condition must have sufficiently large changes in MedPF (signal)--at least larger than the variability inherent in the MedPF (noise)--to constitute a valid measure.

Entities:  

Mesh:

Year:  1998        PMID: 9840895     DOI: 10.1016/s1050-6411(97)00041-2

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  4 in total

1.  The use of non-amplitude components of the myoelectric signal in identifying differences in function between the low back injured and controls.

Authors:  Gregory J Lehman
Journal:  J Can Chiropr Assoc       Date:  2004-09

2.  Muscle recovery from a short fatigue test and consequence on the reliability of EMG indices of fatigue.

Authors:  Christian Larivière; Denis Gravel; A Bertrand Arsenault; Denis Gagnon; Patrick Loisel
Journal:  Eur J Appl Physiol       Date:  2003-02-01       Impact factor: 3.078

3.  EMG recovery and ratings after back extensor fatigue in patients with lumbar disc herniation and healthy subjects.

Authors:  Asa Dedering; Britt Elfving; Gunnar Németh
Journal:  Eur J Appl Physiol       Date:  2004-03-16       Impact factor: 3.078

4.  Training induced fatigability assessed by sEMG in Pre-Olympic ice-skaters.

Authors:  Paweł Pakosz; Mariusz Konieczny
Journal:  Sci Rep       Date:  2020-08-26       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.