Literature DB >> 9840040

Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study.

X Yang1, B D Bolster, D L Kraitchman, E Atalar.   

Abstract

PURPOSE: To develop a new method for monitoring balloon angioplasty by using an intravascular magnetic resonance (MR) imaging technique.
MATERIALS AND METHODS: Nine New Zealand White rabbits were used: seven for technique refinement, including surgery, device insertion, stenosis creation, and MR protocol development; and two for the final MR imaging of the balloon angioplasty. The in vivo experimental method involved insertion of a catheter antenna and a balloon catheter, via femoral arteriotomies bilaterally, into the target site of the upper abdominal aorta, where a stenosis was artificially created by binding a plastic cable tie. Then, the entire process of the dilation of the stenosis with balloon inflation was monitored under MR fluoroscopy.
RESULTS: Catheter insertions were successful, and a 5-mm-long stenosis of the aorta was produced in all nine rabbits. Eight complete balloon angioplasty procedures were satisfactorily monitored and recorded, showing clearly the stenosis of the aorta at the beginning of the procedure, the dilation of the stenosis during the balloon inflation, and the complete opening of the stenosis after balloon dilation.
CONCLUSION: Preliminary results of in vivo balloon angioplasty monitored with intravascular MR imaging are presented. MR fluoroscopy, based on the intravascular MR imaging technique, may represent a potential alternative to x-ray fluoroscopy for guiding interventional treatment of cardiovascular diseases.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9840040     DOI: 10.1016/s1051-0443(98)70429-4

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  10 in total

1.  Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine.

Authors:  Jordin D Green; Reed A Omary; Brian E Schirf; Richard Tang; Biao Lu; James A Gehl; J Jenny Huang; James C Carr; F Scott Pereles; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

3.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 4.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

5.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

6.  MR imaging of hydrogel filament embolic devices loaded with superparamagnetic iron oxide or gadolinium.

Authors:  Monika Killer; Edward M Keeley; Gregory M Cruise; Anne Schmitt; Mark R McCoy
Journal:  Neuroradiology       Date:  2010-07-13       Impact factor: 2.804

Review 7.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

8.  7 Tesla MRI with a transmit/receive loopless antenna and B1-insensitive selective excitation.

Authors:  M Arcan Erturk; AbdEl-Monem M El-Sharkawy; Jay Moore; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2013-08-20       Impact factor: 4.668

Review 9.  Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Authors:  Fabio Settecase; Alastair J Martin; Prasheel Lillaney; Aaron Losey; Steven W Hetts
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

Review 10.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.