Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry.

H Tölli1, K A Johansson.   

Abstract

This paper presents experimentally determined correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry. The correction factors were determined from measurements made in a PMMA phantom and calculation of ratios of measured charges. The ratios were corrected for the different volumes of the ionization chambers, determined in external high-energy electron beams. The correction factors for the central electrode effect and the wall material dependency in 60Co brachytherapy dosimetry agree with those used in external 60Co beam dosimetry. In 192Ir dosimetry, the central aluminium electrode increases the response of an NE2571 chamber compared with that of a chamber with a central graphite electrode. The increase is 1.1 and 2.1% at 1.5 and 5.0 g cm(-2) distance, respectively. Similar values are obtained with an NE2577 chamber. The wall correction factor in 192Ir dosimetry for a chamber with an A-150 wall has been determined to be 1.018, independent of the measurement distance. For a graphite walled chamber, the correction factor is 0.996 and 1.001 at 1.5 and 5.0 g cm(-2) distance, respectively. The values of the wall correction factors are evaluated by a theory presented. If the chamber is used according to the 'large cavity' principle, the correction factor to account for the replacement of the phantom material by the ionization chamber was determined to be 0.982 for an NE2571 chamber when used with a Delrin cap, and 0.978 for an NE2581 when used with a polystyrene cap. The correction factors for the 'large cavity' principle are valid at both 60Co and 192Ir qualities.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9832009     DOI: 10.1088/0031-9155/43/11/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  The Measurement of the Air-Kerma Rate in Air and a Solid Phantom with Ionization Chambers for a 192Ir HDR Brachytherapy Source.

Authors:  Jing Zeng; Pengpeng Qu; Qingsong Pang; Ping Wang
Journal:  Cancer Manag Res       Date:  2020-10-29       Impact factor: 3.989

2.  Comparison of TLD calibration methods for 192Ir dosimetry.

Authors:  Annette Haworth; Duncan J Butler; Lisa Wilfert; Martin A Ebert; Stephen P Todd; Anna J M Hayton; Tomas Kron
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.