Literature DB >> 9831092

Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance.

W T Zaluska1, D Schneditz, A M Kaufman, A T Morris, N W Levin.   

Abstract

Whole body bioimpedance is considered helpful in monitoring the removal of excess body water by ultrafiltration in hemodialysis patients. In this study, the cumulative, estimated decrease in extracellular volume (V(est)) modeled from whole body bioimpedance data was compared with measured volume (Vmeas) removed by ultrafiltration (UFR = 1.01 +/- 0.31 L/hr) in 12 patients during 36 high efficiency hemodialysis treatments. In the mean, estimated (V(est) = 3.0 +/- 1.4 L) and measured volumes (Vmeas = 3.4 +/- 1.1 L) correlated linearly: V(est) = 1.05 x Vmeas - 0.60, r2 = 0.68. Patients developed hypotension in half the treatments. Except for a larger decrease in systolic blood pressures in hypotensive (34 +/- 24 mmHg) vs. stable (14 +/- 15 mmHg) treatments, patient and treatment characteristics were not different between groups. However, at the end of hemodialysis, the difference V(est) - Vmeas was -0.8 +/- 0.9 L in hypotensive, and only 0.1 +/- 0.4 L in stable patients (p < 0.05). The difference between V(est) and Vmeas can be explained by a predominant removal of excess body water from central body compartments such as the trunk and the central blood volume during hypotension. These compartments are not adequately measured by whole body bioimpedance techniques. However, this information could be helpful in identifying patients with delayed peripheral fluid removal that may occur when either target weight is too low or UFR rates are too high.

Entities:  

Mesh:

Year:  1998        PMID: 9831092     DOI: 10.1097/00002480-199811000-00011

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Electrical admittance method for estimating fluid removal during artificial dialysis.

Authors:  K Sakamoto; H Kanai; N Furuya
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

Review 2.  Fluid balance and acute kidney injury.

Authors:  John R Prowle; Jorge E Echeverri; E Valentina Ligabo; Claudio Ronco; Rinaldo Bellomo
Journal:  Nat Rev Nephrol       Date:  2009-12-22       Impact factor: 28.314

3.  Intra-abdominal pressure correlates with extracellular water content.

Authors:  Wojciech Dąbrowski; Edyta Kotlinska-Hasiec; Andrzej Jaroszynski; Przemyslaw Zadora; Jacek Pilat; Ziemowit Rzecki; Wojciech Zaluska; Daniel Schneditz
Journal:  PLoS One       Date:  2015-04-07       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.