Electrical admittance method for estimating fluid removal during artificial dialysis.

K Sakamoto1, H Kanai, N Furuya.   

Abstract

Because the conductivity of blood changes remarkably during artificial dialysis, sometimes by more than 20%, changes in tissue admittance at low frequency are caused by changes not only in the extracellular fluid volume but also in blood conductivity. Therefore the changes in blood conductance due to artificial dialysis must be considered for the estimation of water removal by the admittance method. An accurate bio-impedance measurement system was developed. Measurement error was less than 1% at low frequency and 10% at high frequency. A new electrical bio-admittance method (NAM) was evaluated for the continuous measurement of removed fluid volume, using a three parallel-compartment tissue model, consisting of intracellular, interstitial and blood compartments, which takes into account the blood conductivity change. NAM used the equivalent conductivity calculated from the leg admittances of patients, measured at 1 min intervals during various artificial dialysis procedures. The actual amount of excess water removed by ultra-filtration agreed with the NAM-estimated amount within an error of 20%. NAM was also applied to estimate the intra- and extracellular fluid changes. The results were consistent with the physiological changes known to occur during the various forms of dialysis.

Entities:  

Mesh:

Year:  2004        PMID: 15191082     DOI: 10.1007/bf02344712

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Study of the relation between fluid distribution change in tissue and impedance change during hemodialysis by frequency characteristics of the flowing blood.

Authors:  K Sakamoto; R Sunaga; K Nakamura; Y Sato; M Fujii; H Kanai; T Tsuchida; A Ueno; N Kanai; K Hasegawa
Journal:  Ann N Y Acad Sci       Date:  1999-04-20       Impact factor: 5.691

2.  On the limits of ellipsoidal models when analyzing dielectric behavior of living cells. Emphasis on red blood cells.

Authors:  E Gheorghiu
Journal:  Ann N Y Acad Sci       Date:  1999-04-20       Impact factor: 5.691

3.  Determination of total body water by multifrequency bio-electric impedance: development of several models.

Authors:  B K van Kreel; N Cox-Reyven; P Soeters
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

4.  The specific resistance of blood at body temperature.

Authors:  L A Geddes; C Sadler
Journal:  Med Biol Eng       Date:  1973-05

5.  Measurement of body fluid volume change using multisite impedance measurements.

Authors:  R Patterson; C Ranganathan; R Engel; R Berkseth
Journal:  Med Biol Eng Comput       Date:  1988-01       Impact factor: 2.602

6.  A practical analysis of the electrical conductivity of blood.

Authors:  E D Trautman; R S Newbower
Journal:  IEEE Trans Biomed Eng       Date:  1983-03       Impact factor: 4.538

7.  [Estimation of fluid distribution by impedance method].

Authors:  M Haeno; H Tagawa; K Sakamoto; H Kanai
Journal:  Iyodenshi To Seitai Kogaku       Date:  1985-10

8.  Noninvasive measurement of hematocrit by electrical admittance plethysmography technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

9.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05

10.  Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance.

Authors:  W T Zaluska; D Schneditz; A M Kaufman; A T Morris; N W Levin
Journal:  ASAIO J       Date:  1998 Nov-Dec       Impact factor: 2.872

View more
  1 in total

1.  Model-based correction of the influence of body position on continuous segmental and hand-to-foot bioimpedance measurements.

Authors:  Guillermo Medrano; Frank Eitner; Marian Walter; Steffen Leonhardt
Journal:  Med Biol Eng Comput       Date:  2010-04-20       Impact factor: 2.602

  1 in total