Literature DB >> 9830655

Observer differentiation of mechanical defects versus natural dental caries cavitations on monitor-displayed images with imaging plate readout.

B C Kang1, L J Goldsmith, A G Farman.   

Abstract

OBJECTIVE: The purpose of this study was to compare the ability of dentists to detect mechanically created defects vs natural dental caries cavitations on the proximal surfaces of extracted teeth by means of storage phosphor imaging plate technology. STUDY
DESIGN: Fifty-two extracted molar and premolar teeth were blocked into sets for bitewing radiographs through use of the DIGORA digital imaging system. Sixteen natural caries cavities and 28 artificial lesions were present in the 80 proximal surfaces included in the study. A group of 16 dentists assessed proximal lesions on unenhanced images on the monitor and 1 month later on contrast-enhanced images. A different group of 16 dentists assessed proximal lesions on contrast-enhanced images and 1 month later on unenhanced images. The Mann-Whitney U test was used to check for a reading-order effect. The Zelen test of odds ratio was used to test for homogeneity, and the Mantel-Haenszel analysis or stratified logistic regression was used for inference about the common odds ratio. Alpha was set at P < .05. RESULTS AND
CONCLUSIONS: With the DIGORA system, there was little difference between the detection rates of mechanical defects and natural carious cavities with unenhanced images, but the mechanical defects were more readily detected when contrast-enhanced images were used. Cavity depth positively affected the odds of diagnosis of lesions, with deeper lesions being more readily detected than more superficial ones irrespective of whether they were natural or artificial. In comparison with findings of previous studies in which film and a charge-coupled device detector were used, the overall detection rate for natural dental caries was remarkably constant across the modalities.

Entities:  

Mesh:

Year:  1998        PMID: 9830655     DOI: 10.1016/s1079-2104(98)90353-5

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  4 in total

1.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

2.  Influence of the display monitor on observer performance in detection of dental caries.

Authors:  Farzad Esmaeili; Esrafil Balaei; Firoz Pouralibaba; Farzaneh Kaviani; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-09-10

3.  Comparison of diagnostic methods for early interproximal caries detection with near-infrared light transillumination: an in vivo study.

Authors:  Ismail Hakki Baltacioglu; Kaan Orhan
Journal:  BMC Oral Health       Date:  2017-11-16       Impact factor: 2.757

4.  In vitro induction of enamel subsurface demineralization for evaluation of diagnostic imaging methods.

Authors:  Rívea Inês Ferreira; Francisco Haiter-Neto; Cínthia Pereira Machado Tabchoury; Frab Norberto Bóscolo
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.