Literature DB >> 9828061

In vitro thrombogenicity testing of artificial organs.

R Paul1, O Marseille, E Hintze, L Huber, H Schima, H Reul, G Rau.   

Abstract

Thromboembolic complications remain as one of the main problems for blood contacting artificial organs such as heart valves, bloodpumps and others. In vitro evaluation of thrombogenesis in prototypes has not previously been part of the standard evaluation of these devices. In comparison to hemolysis testing, evaluation of the thrombogenic potential is more difficult to perform because of the complexity of the blood coagulation system. We present an in vitro testing procedure that allows the accelerated examination of the thrombogenic potential of different types of blood pumps. Additionally, first results are presented that indicate the reliability of the accelerated clotting test for mechanical heart valves. Results for the centrifugal pump BioMedicus and two microaxial pumps have shown typical thrombus formation at locations such as bearings. The results indicate that the accelerated clotting test is an excellent addition to the much more expensive animal testing of artificial organs or assist devices. In vitro testing permits studies of thrombus formation to be performed at an early stage and at low costs and also facilitates a more precise investigation of device areas known to be potential hot spots for thrombus formation.

Entities:  

Mesh:

Year:  1998        PMID: 9828061

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  4 in total

1.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

Review 2.  Towards non-thrombogenic performance of blood recirculating devices.

Authors:  D Bluestein; K B Chandran; K B Manning
Journal:  Ann Biomed Eng       Date:  2010-02-04       Impact factor: 3.934

3.  Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements.

Authors:  Matteo Nobili; Jawaad Sheriff; Umberto Morbiducci; Alberto Redaelli; Danny Bluestein
Journal:  ASAIO J       Date:  2008 Jan-Feb       Impact factor: 2.872

4.  Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.

Authors:  Danny Bluestein; Gaurav Girdhar; Shmuel Einav; Marvin J Slepian
Journal:  J Biomech       Date:  2012-12-06       Impact factor: 2.712

  4 in total