Literature DB >> 9823128

The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys.

C Canalda-Sahli1, E Brau-Aguadé, J Sentís-Vilalta.   

Abstract

The purpose of this study was to assess the effect of dry-heat or autoclave sterilization on the resistance to fracture in torque and angular deflection and the resistance to bending of K-type files made of nickel-titanium (Nitiflex, Naviflex), titanium (Microtitane) or stainless steel (Flexofile, Flex-R). Ten K-type files of each sort, from size 25 to 40, were tested, according to ANSI/ADA specification 28 (1988) and ISO specification 3630 (1992). Sterilization with dry heat and autoclave slightly decreased the flexibility of files made of stainless steel and nickel-titanium for most of the sizes, although the values obtained satisfied ISO specifications. The files made of titanium showed an increased flexibility after sterilization with autoclave (sizes 30 and 35) and dry heat (sizes 30, 35 and 40). Resistance to fracture varied amongst the five groups of files tested as follows: it decreased in some sizes of stainless-steel instruments, decreased in all sizes of titanium files assessed by the torsional moment, and either increased or decreased in some sizes of nickel-titanium files. All files tested, however, satisfied relevant standards for angular deflection after being subjected to sterilization with an autoclave or dry heat.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9823128

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation.

Authors:  Ashish Shashikant Nair; Mahima Tilakchand; Balaram Damodar Naik
Journal:  J Conserv Dent       Date:  2015 May-Jun

2.  The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2017-11-02

3.  Laboratory Rational of Changes in the Crystal Lattice of Nickel-Titanium Endodontic Rotary Files in Autoclaving.

Authors:  Zurab Khabadze; Oleg Mordanov; Mariya Balashova; Leonid Stolov; Amaliya Pangratyan; Roza Bokova; Shamil Nazhmudinov; Shamil Solimanov; Anastasiya Kuznetsova; Anzhela Adzhieva; Omargadzhi Magomedov
Journal:  Int J Dent       Date:  2020-01-25

4.  Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files.

Authors:  Emad O Alshwaimi
Journal:  Saudi J Med Med Sci       Date:  2019-02-08

Review 5.  Management of Instrument Sterilization Workflow in Endodontics: A Systematic Review and Meta-Analysis.

Authors:  Mario Dioguardi; Diego Sovereto; Gaetano Illuzzi; Enrica Laneve; Bruna Raddato; Claudia Arena; Vito Carlo Alberto Caponio; Giorgia Apollonia Caloro; Khrystyna Zhurakivska; Giuseppe Troiano; Lorenzo Lo Muzio
Journal:  Int J Dent       Date:  2020-02-08
  5 in total