Literature DB >> 9812080

Relation between impedance and electrode temperature during radiofrequency catheter ablation of accessory pathways and atrioventricular nodal reentrant tachycardia.

E Nsah1, R Berger, L Rosenthal, R Hui, B Ramza, P Jumrussirikul, J H Lawrence, G Tomaselli, D Kass, H Calkins.   

Abstract

OBJECTIVES: Impedance monitoring has been proposed as a method to assess the adequacy of tissue heating during catheter ablation procedures. The purpose of this study was to evaluate the relation among initial impedance, fall in impedance, and electrode temperature during catheter ablation procedures. METHODS AND
RESULTS: Data from 248 applications of radiofrequency energy in 45 consecutive patients (26 with accessory pathways and 19 with atrioventricular nodal reentrant tachycardia) referred for catheter ablation were analyzed. The initial impedance was higher during ablation of accessory pathways than during atrioventricular nodal reentrant tachycardia (116+/-66 versus 106+/-80 omega, P < .001). In both groups, a significant correlation was observed between the initial impedance and temperature (R = 0.98, P < .001). After accounting for differences between patients and ablation targets, an even closer correlation was observed (accessory pathways: R = 0.95, P < .0001; atrioventricular nodal reentrant tachycardia: R = 0.94, P < .0001).
CONCLUSION: These data suggest that monitoring of the initial impedance and the fall in impedance during ablation procedures may provide clinically valuable information to assess the efficacy of tissue heating and lesion formation.

Entities:  

Mesh:

Year:  1998        PMID: 9812080     DOI: 10.1016/s0002-8703(98)70130-9

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Radiofrequency ablation data associated with atrioesophageal fistula.

Authors:  David R Tomlinson; John Mandrola
Journal:  HeartRhythm Case Rep       Date:  2021-12-15

2.  Effect of Baseline Impedance in Radiofrequency Delivery on Lesion Characteristics and the Relationship Between Impedance and Steam Pops.

Authors:  Lijuan Qu; Min Guo; Meng Sun; Rui Wang; Nan Zhang; Xin Li
Journal:  Front Cardiovasc Med       Date:  2022-04-27

3.  Lumped Element Electrical Model based on Three Resistors for Electrical Impedance in Radiofrequency Cardiac Ablation: Estimations from Analytical Calculations and Clinical Data.

Authors:  Enrique Berjano; Andre d'Avila
Journal:  Open Biomed Eng J       Date:  2013-07-12

4.  The impacts of contact force, power and application time on ablation effect indicated by serial measurements of impedance drop in both conventional and high-power short-duration ablation settings of atrial fibrillation.

Authors:  Li-Bin Shi; Yu-Chuan Wang; Song-Yun Chu; Alessandro De Bortoli; Peter Schuster; Eivind Solheim; Jian Chen
Journal:  J Interv Card Electrophysiol       Date:  2021-04-23       Impact factor: 1.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.