PURPOSE: Three patients with acute hepatitis B virus infection were identified who had been hospitalized on the same medical ward during a 19-day period several months earlier. An investigation was undertaken to determine if nosocomial transmission had occurred. SUBJECTS AND METHODS: A cohort study of patients admitted to the medical ward during the 19-day period in 1995 was conducted. In addition, we reviewed medical charts and laboratory records of all patients with acute hepatitis B virus infection who had been admitted to the hospital from 1992 through October 1996 to identify other cases with possible nosocomial acquisition.
RESULTS: The 3 patients who had developed acute hepatitis B infection 2 to 5 months after hospitalization on the same medical ward had diabetes mellitus but no identified risk factors for hepatitis B infection. A source patient with diabetes mellitus and hepatitis B "e" antigenemia also was present on the same medical ward at the same time; all 4 patients were infected with the same viral subtype (adw2). Diabetes mellitus and fingerstick monitoring were associated with illness (P <0.001). Through the review of medical charts and laboratory records, 11 additional cases of suspected nosocomial acquisition via fingersticks were identified in 1996, including two clusters involving an unusual subtype of hepatitis B virus (adw4). The fingerstick device employed had a reusable base onto which disposable lancet caps were inserted. There was ample opportunity for cross-contamination among patients because deficiencies in infection control practices, particularly failure to change gloves between patients, were reported by nurses and patients with diabetes mellitus.
CONCLUSION: Transmission during fingerstick procedures was the most likely cause of these cases of nosocomial hepatitis B infection. Contamination probably occurred when healthcare workers failed to change gloves between patients undergoing fingerstick monitoring, although other means of contamination cannot be ruled out.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9809690     DOI: 10.1016/s0002-9343(98)00256-3

Source DB:  PubMed          Journal:  Am J Med        ISSN: 0002-9343            Impact factor:   4.965


  5 in total

1.  Effect of disinfectants on glucose monitors.

Authors:  John J Mahoney; Christine G Lim
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

2.  Outbreak of hepatitis B in a nursing home associated with capillary blood sampling.

Authors:  J M Dreesman; A Baillot; L Hamschmidt; M Monazahian; U C Wend; W H Gerlich
Journal:  Epidemiol Infect       Date:  2006-01-26       Impact factor: 2.451

3.  Eliminating the blood: ongoing outbreaks of hepatitis B virus infection and the need for innovative glucose monitoring technologies.

Authors:  Nicola D Thompson; Joseph F Perz
Journal:  J Diabetes Sci Technol       Date:  2009-03-01

4.  Hepatitis B vaccine immunogenicity among adults vaccinated during an outbreak response in an assisted living facility--Virginia, 2010.

Authors:  Thomas John Bender; Umid Sharapov; Okey Utah; Jian Xing; Dale Hu; Jolanta Rybczynska; Jan Drobeniuc; Saleem Kamili; Philip R Spradling; Anne C Moorman
Journal:  Vaccine       Date:  2013-12-23       Impact factor: 3.641

5.  Outbreak of hepatitis B virus infections associated with assisted monitoring of blood glucose in an assisted living facility-Virginia, 2010.

Authors:  Thomas John Bender; Matthew E Wise; Okey Utah; Anne C Moorman; Umid Sharapov; Jan Drobeniuc; Yury Khudyakov; Marielle Fricchione; Mary Beth White-Comstock; Nicola D Thompson; Priti R Patel
Journal:  PLoS One       Date:  2012-12-26       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.