Literature DB >> 9807561

Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: laboratory and clinical experience in liver metastases.

S N Goldberg1, L Solbiati, P F Hahn, E Cosman, J E Conrad, R Fogle, G S Gazelle.   

Abstract

PURPOSE: To evaluate whether coagulation necrosis achievable with radio-frequency (RF) ablation can be increased by using a cluster of closely spaced electrodes.
MATERIALS AND METHODS: RF was applied to ex vivo liver (n = 68), in vivo liver (n = 12), and in vivo muscle (n = 15) by using a cluster array of three separate internally cooled electrodes spaced 0.5 cm apart. The diameter of coagulation necrosis achieved with optimal RF deposition (1,400-2,150 peak mA) for 5-60 minutes of RF application was determined for electrode tip lengths of 1.5-3.0 cm and compared with that obtained by using a single electrode and otherwise similar technique. Ten patients with solitary intrahepatic colorectal metastases were also treated by using cluster electrode RF ablation.
RESULTS: In ex vivo liver, simultaneous RF application to electrode clusters for 15, 30, and 45 minutes produced 4.7 cm +/- 0.1, 6.2 cm +/- 0.1, and 7.0 cm +/- 0.2 of coagulation necrosis, respectively. In in vivo liver and muscle, RF applied to electrode clusters for 12 minutes yielded 3.1 cm +/- 0.2 and 7.6 cm +/- 0.4 of coagulation, respectively. RF application to a single electrode produced maximal coagulation of 2.9 cm in ex vivo liver, 1.8 cm in in vivo liver, and 4.3 cm in muscle (P < .01, all tissues). In colorectal metastases, a single 12-15-minute application of RF to an electrode cluster induced 4.5-7.0 cm of coagulation necrosis.
CONCLUSION: Simultaneous RF application to a cluster of three closely spaced internally cooled electrodes enables a larger volume of coagulation in ex vivo liver, in vivo tissues, and hepatic colorectal metastases than previously reported.

Entities:  

Mesh:

Year:  1998        PMID: 9807561     DOI: 10.1148/radiology.209.2.9807561

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  63 in total

1.  Tissue contraction caused by radiofrequency and microwave ablation: a laboratory study in liver and lung.

Authors:  Christopher L Brace; Teresa A Diaz; J Louis Hinshaw; Fred T Lee
Journal:  J Vasc Interv Radiol       Date:  2010-05-27       Impact factor: 3.464

Review 2.  Principles of and advances in percutaneous ablation.

Authors:  Muneeb Ahmed; Christopher L Brace; Fred T Lee; S Nahum Goldberg
Journal:  Radiology       Date:  2011-02       Impact factor: 11.105

3.  Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system.

Authors:  Jeong Min Lee; Joon Koo Han; Se Hyung Kim; Kyu Li Sohn; Seung Hong Choi; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2004-07-10       Impact factor: 5.315

4.  Multiple-electrode radiofrequency ablations using Octopus® electrodes in an in vivo porcine liver model.

Authors:  E S Lee; J M Lee; W S Kim; S H Choi; I Joo; M Kim; D H Yoo; R-E Yoo; J K Han; B I Choi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

5.  Maximizing parameters for tissue ablation by using an internally cooled electrode.

Authors:  John P McGahan; Shaun Loh; Fernando J Boschini; Eric E Paoli; John M Brock; Wayne L Monsky; Chin-Shang Li
Journal:  Radiology       Date:  2010-06-08       Impact factor: 11.105

6.  Thermal ablation for unresectable liver tumours, time to move forward?

Authors:  Gianpiero Gravante
Journal:  World J Gastrointest Surg       Date:  2010-01-27

Review 7.  Radiofrequency thermal ablation of liver tumors.

Authors:  Elisabetta Buscarini; Agostino Savoia; Gianfranco Brambilla; Fernanda Menozzi; Luigi Reduzzi; Deike Strobel; Johannes Hänsler; Luigi Buscarini; Luigi Gaiti; Alessandro Zambelli
Journal:  Eur Radiol       Date:  2005-03-08       Impact factor: 5.315

Review 8.  Electrodes and multiple electrode systems for radiofrequency ablation: a proposal for updated terminology.

Authors:  Stefaan Mulier; Yi Miao; Peter Mulier; Benoit Dupas; Philippe Pereira; Thierry de Baere; Riccardo Lencioni; Raymond Leveillee; Guy Marchal; Luc Michel; Yicheng Ni
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

Review 9.  Radiofrequency and microwave ablation of the liver, lung, kidney, and bone: what are the differences?

Authors:  Christopher L Brace
Journal:  Curr Probl Diagn Radiol       Date:  2009 May-Jun

10.  Clinical short-term results of radiofrequency ablation in liver cancers.

Authors:  Hong-Chi Jiang; Lian-Xin Liu; Da-Xun Piao; Jun Xu; Min Zheng; An-Long Zhu; Shu-Yi Qi; Wei-Hui Zhang; Lin-Feng Wu
Journal:  World J Gastroenterol       Date:  2002-08       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.