Optimal time spacings for T2 measurements: monoexponential and biexponential systems.

R I Shrager1, G H Weiss, R G Spencer.   

Abstract

We have developed an optimal design strategy, i.e. a choice of times at which the magnetization should be measured, in spin-echo measurements, when the number of measurements is fixed in advance. Results are given for samples whose relaxation is described by either an exponential or biexponential decay curve. The analysis is based on having an initial estimate of the ranges in which the relaxation times are likely to lie. The optimal design consists of a set of easily parameterized non-uniformly spaced measurement times, as opposed to present implementation of spin-echo experiments. Analysis of the biexponential case shows that an order of magnitude greater signal-to-noise is required to achieve T2 estimates of comparable precision to monoexponential measurements with the same number of data points. The optimal designs lead to an improved ability to discriminate between two relatively similar relaxation times.

Mesh:

Year:  1998        PMID: 9802472     DOI: 10.1002/(sici)1099-1492(199810)11:6<297::aid-nbm531>3.0.co;2-a

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  15 in total

1.  Echo-spacing optimization for the simultaneous measurement of reversible (R2') and irreversible (R2) transverse relaxation rates.

Authors:  Ruitian Song; Hee Kwon Song
Journal:  Magn Reson Imaging       Date:  2006-11-13       Impact factor: 2.546

2.  Limits of a localized magnetic resonance spectroscopy assay for ex vivo myocardial triacylglycerol.

Authors:  Robert D O'Connor; Robert J Gropler; Linda Peterson; Jean Schaffer; Joseph J H Ackerman
Journal:  J Pharm Biomed Anal       Date:  2007-09-01       Impact factor: 3.935

Review 3.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

4.  Compressed sensing acceleration of biexponential 3D-T relaxation mapping of knee cartilage.

Authors:  Marceo V W Zibetti; Azadeh Sharafi; Ricardo Otazo; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

5.  Optimization of b-value sampling for diffusion-weighted imaging of the kidney.

Authors:  Jeff L Zhang; Eric E Sigmund; Henry Rusinek; Hersh Chandarana; Pippa Storey; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

6.  Improved in vivo measurement of myocardial transverse relaxation with 3 Tesla magnetic resonance imaging.

Authors:  Jared Guthrie Cobb; Cynthia B Paschal
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

7.  On the measurement of multi-component T2 relaxation in cartilage by MR spectroscopy and imaging.

Authors:  ShaoKuan Zheng; Yang Xia
Journal:  Magn Reson Imaging       Date:  2010-01-12       Impact factor: 2.546

8.  Bayesian analysis of transverse signal decay with application to human brain.

Authors:  Mustapha Bouhrara; David A Reiter; Richard G Spencer
Journal:  Magn Reson Med       Date:  2014-09-19       Impact factor: 4.668

Review 9.  Rapid compositional mapping of knee cartilage with compressed sensing MRI.

Authors:  Marcelo V W Zibetti; Rahman Baboli; Gregory Chang; Ricardo Otazo; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2018-10-08       Impact factor: 4.813

10.  Optimal echo spacing for multi-echo imaging measurements of Bi-exponential T2 relaxation.

Authors:  Adrienne N Dula; Daniel F Gochberg; Mark D Does
Journal:  J Magn Reson       Date:  2008-11-12       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.