Literature DB >> 9800821

Pulsed Doppler intraoperative flow assessment and midterm coronary graft patency.

Y A Louagie1, C E Brockmann, J Jamart, E Schroeder, M Buche, P M Eucher, J C Schoevaerdts.   

Abstract

BACKGROUND: This study was designed to assess the value of hemodynamic measurements taken intraoperatively in predicting midterm patency of coronary bypass grafts.
METHODS: A pulsed Doppler flowmeter was routinely used during operation to determine the hemodynamic parameters of coronary bypass grafts. During a 7-year period, 85 patients underwent angiographic evaluation. As a result, a thorough hemodynamic assessment of 214 grafts (89 arterial and 125 venous) at initial operation was available for analysis.
RESULTS: The overall patency rate was 88.3%. The mean flow measured intraoperatively in 168 intact grafts was 60+/-3 mL/min (range, 9 to 230 mL/min), and the resistance was 1.8+/-0.1 peripheral resistance units (range, 0.3 to 9.0 peripheral resistance units). The mean flow was 36+/-5 mL/min (range, 2 to 107 mL/min), and the resistance was 5.9+/-2.0 peripheral resistance units (range, 0.6 to 46.0 peripheral resistance units) in 25 grafts found occluded at angiographic evaluation. Multivariate analysis identified three independent variables associated with a reduced patency rate: increased resistance as measured in the graft (p = 0.012), increasing interval of control angiography (p = 0.006), and preoperative cardiogenic shock (p = 0.040).
CONCLUSIONS: The prognosis for midterm patency of aortocoronary bypass grafts depends on the intraoperative hemodynamic status.

Entities:  

Mesh:

Year:  1998        PMID: 9800821     DOI: 10.1016/s0003-4975(98)00777-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Anastomotic quality in CABG: when life depends on millimetres.

Authors:  Trevor Bardell; G Andrew Y Hamilton; Douglas H Bergstrome; Mohamed J Ali
Journal:  CMAJ       Date:  2002-10-01       Impact factor: 8.262

2.  Intraoperative assessment and quantification of coronary artery graft patency performed on or off cardiopulmonary bypass.

Authors:  Eric D Rauch; Christopher Leach; Terry Barnes; Kurt Driscoll; Kurt Strutz; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-06

3.  Contrast-enhanced cardiac MRI before coronary artery bypass surgery: impact of myocardial scar extent on bypass flow.

Authors:  Peter Hunold; Parwis Massoudy; Claudia Boehm; Thomas Schlosser; Kai Nassenstein; Stephan Knipp; Holger Eggebrecht; Matthias Thielmann; Raimund Erbel; Heinz Jakob; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2008-06-26       Impact factor: 5.315

  3 in total