Literature DB >> 9800713

Morphometric texture analysis of spinal trabecular bone structure assessed using orthogonal radiographic projections.

X Ouyang1, S Majumdar, T M Link, Y Lu, P Augat, J Lin, D Newitt, H K Genant.   

Abstract

The measurement of bone microstructure as well as bone mineral density may improve the estimation of bone strength. Cubic specimens (N = 26, 12 mm X 12 mm X 12 mm) of human cadaver vertebrae were cut along three orthogonal anatomic orientations, i.e., superior-inferior (SI), medial-lateral (ML), and anterior-posterior (AP). Contact radiographs of the bone cubes along all three orientations were obtained and then digitized by a laser scanner with pixel size of 50 microns x 50 microns. The specimens were tested in compression along the 3 orthogonal orientations and the Young's modulus (YM) was calculated for each direction. Quantitative computed tomography (QCT) was used to obtain a measure of trabecular bone mineral density (BMD). Global gray level thresholding and local thresholding algorithms were used to extract the trabecular bone network. Apparent trabecular bone fraction (ABV/TV), mean intercept length (I.TH), mean intercept separation (I.SP), and number of nodes (N.ND) were measured from the extracted trabecular network. Fractal dimension (Fr.D) of the trabecular bone texture was also measured. Paired t-tests showed that the mean values of each texture parameter (except ABV/TV) and of YM along the SI direction were significantly different (p < 0.05) from those along the ML and AP direction. However, the mean values along the ML and AP directions were not significantly different. Multivariate regression of YM as a function of the texture parameters and BMD showed that without adjusting for the effect of BMD, YM was significantly explained by all the texture parameters (R2 = 0.2-0.6). When BMD was included in the regression, although the variations in YM of ML, AP, and SI orientations could be explained by BMD alone, some of the texture parameters did improve the overall prediction of the biomechanical properties, while, some parameters such as ABV/TV and Fr.D in the ML orientation showed a more significant overall effect in explaining mechanical strength than did BMD. In conclusion, trabecular texture parameters correlated significantly with BMD and YM. Trabecular texture parameters from projectional radiographs reflect the anisotropy of trabecular structure. Quantitative radiographic assessment of trabecular structure using fine-detail radiography can potentially improve the estimation of bone strength.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  1998        PMID: 9800713     DOI: 10.1118/1.598391

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  An investigation of thoracic and lumbar cancellous vertebral architecture using power-spectral analysis of plain radiographs.

Authors:  A M Buck; R I Price; I M Sweetman; C E Oxnard
Journal:  J Anat       Date:  2002-05       Impact factor: 2.610

Review 2.  Current technologies in the evaluation of bone architecture.

Authors:  Sharmila Majumdar
Journal:  Curr Osteoporos Rep       Date:  2003-12       Impact factor: 5.096

Review 3.  Current diagnostic techniques in the evaluation of bone architecture.

Authors:  Thomas M Link; Sharmila Majumdar
Journal:  Curr Osteoporos Rep       Date:  2004-06       Impact factor: 5.096

Review 4.  Noninvasive assessment of bone structure.

Authors:  Tamara J Vokes; Murray J Favus
Journal:  Curr Osteoporos Rep       Date:  2003-06       Impact factor: 5.096

5.  Trabecular bone is more deteriorated in spinal cord injured versus estrogen-free postmenopausal women.

Authors:  Jill M Slade; C Scott Bickel; Christopher M Modlesky; Sharmila Majumdar; Gary A Dudley
Journal:  Osteoporos Int       Date:  2004-08-28       Impact factor: 4.507

6.  Radiographic trabecular 2D and 3D parameters of proximal femoral bone cores correlate with each other and with yield stress.

Authors:  D Steines; S-W Liew; C Arnaud; R Vargas-Voracek; A Nazarian; R Müller; B Snyder; P Hess; P Lang
Journal:  Osteoporos Int       Date:  2009-03-25       Impact factor: 4.507

7.  Local soft tissue compression enhances fracture healing in a rabbit fibula.

Authors:  Simon Morr; Ernest C Chisena; Emre Tomin; Michael Mangino; Joseph M Lane
Journal:  HSS J       Date:  2009-11-13

Review 8.  The Founder's Lecture 2009: advances in imaging of osteoporosis and osteoarthritis.

Authors:  Thomas Marc Link
Journal:  Skeletal Radiol       Date:  2010-06-20       Impact factor: 2.199

9.  Diagnosis of osteoporosis from dental panoramic radiographs using the support vector machine method in a computer-aided system.

Authors:  M S Kavitha; Akira Asano; Akira Taguchi; Takio Kurita; Mitsuhiro Sanada
Journal:  BMC Med Imaging       Date:  2012-01-16       Impact factor: 1.930

10.  Standardizing compression testing for measuring the stiffness of human bone.

Authors:  S Zhao; M Arnold; S Ma; R L Abel; J P Cobb; U Hansen; O Boughton
Journal:  Bone Joint Res       Date:  2018-09-15       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.