Literature DB >> 9800711

An evaluation of the signal and noise characteristics of four CCD-based film digitizers.

N J Hangiandreou1, T J O'Connor, J P Felmlee.   

Abstract

Film digitizers are common devices in radiology departments involved with picture archive and communication systems (PACS) and teleradiology. In this paper, we studied the performance of film digitizers based on charge-coupled device detectors (CCD digitizers), and compared this with the performance of a laser digitizer (the de facto standard). Our focus was on the assessment of signal, noise and useful optical density range performance. A function (L* delta D) derived from the Rose model was used to evaluate these parameters in absolute terms, based their predicted ability to detect objects of specific size and optical density difference with respect to background. We studied CCD digitizers from four different vendors and found that none was able to reliably operate up to the maximum density of 3.0 required to digitize plain radiographs, while the laser digitizer was capable of this task. Our analysis also indicated that two of the four CCD digitizers were adequate for digitizing laser-printed cross-sectional images in certain cases. Finally, our analysis indicated that digitization of SMPTE pattern films along with visual assessment of the 5% and 95% contrast patches was not sufficient for determining the utility of film digitizers for clinical tasks. Computation of the L* delta D function provides a useful means of assessing the performance of film digitizers (e.g., for acceptance testing and quality control), and this technique may be adaptable for evaluation of other digital imaging modalities.

Mesh:

Year:  1998        PMID: 9800711     DOI: 10.1118/1.598390

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study.

Authors:  Yang Meng; Chris C Shaw; Xinming Liu; Mustafa C Altunbas; Tianpeng Wang; Lingyun Chen; Shu-Ju Tu; S Cheenu Kappadath; Chao-Jen Lai
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-02

2.  Evaluating noise in digitized radiographic images by means of histogram.

Authors:  Izabel Regina Fischer Rubira-Bullen; Maurício Cunha Escarpinati; Homero Schiabel; Marcelo Andrade da Costa Vieira; Cássia Maria Fischer Rubira; José Roberto Pereira Lauris
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

3.  Digitizing radiographic films: a simple way to evaluate indirect digital images.

Authors:  Izabel Regina Fischer Rubia-Bullen; Maurício Cunha Escarpinati; Homero Schiabel; Marcelo Andrade da Costa Vieira; Cássia Maria Fischer Rubira; José Roberto Pereira Lauris
Journal:  J Appl Oral Sci       Date:  2007-02       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.