Literature DB >> 9800694

Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique.

M Partridge1, P M Evans, A Mosleh-Shirazi, D Convery.   

Abstract

The use of intensity-modulated radiation fields in radiotherapy treatment has been shown to have the potential to deliver highly conformal dose distributions. One technique for delivering these intensity-modulated beams is a computerized dynamic multileaf collimator (MLC). A major current impediment to the development of dynamic MLC therapy is verification of these highly complex treatments. Electronic portal imaging is shown here to be a solution to this verification problem. Experimental results are presented showing that leaf penumbra measured with a portal imager can be used to accurately define the positions of moving leaves. The random error in these leaf positions is compared with mean leaf positions along each leaf bank and specified leaf positions at prescription control points to check mechanical performance. Individual leaves are also checked for systematic motion errors. All leaf positions are found to be well within the manufacturer's specifications at all times. Finally, integral intensity images are presented that can be related to the dose distribution delivered. Portal imaging is shown to have the potential to become a valuable tool for the verification of dynamic MLC irradiation.

Mesh:

Year:  1998        PMID: 9800694     DOI: 10.1118/1.598376

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy.

Authors:  Louis Lee; Weihua Mao; Lei Xing
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

2.  Credentialing results from IMRT irradiations of an anthropomorphic head and neck phantom.

Authors:  Andrea Molineu; Nadia Hernandez; Trang Nguyen; Geoffrey Ibbott; David Followill
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

3.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

4.  A method for deconvolution of integrated electronic portal images to obtain incident fluence for dose reconstruction.

Authors:  Wendel Dean Renner; Kevin Norton; Timothy Holmes
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

5.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis.

Authors:  Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Using the frame averaging of aS500 EPID for IMRT verification.

Authors:  J Chang; C C Ling
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  6 in total