Literature DB >> 9800688

A software tool for the quantitative evaluation of 3D dose calculation algorithms.

W B Harms1, D A Low, J W Wong, J A Purdy.   

Abstract

Current methods for evaluating modern radiation therapy treatment planning (RTP) systems include the manual superposition of calculated and measured isodose curves and the comparison of a limited number of calculated and measured point doses. Both techniques have significant limitations in providing quantitative evaluations of the large number of dose data generated by modern RTP systems. More sophisticated comparison techniques have been presented in the literature, including dose-difference and distance-to-agreement (DTA) analyses. A software tool has been developed that uses superimposed isodose plots, dose-difference, and DTA distributions to quantify errors in computed dose distributions. Dose-difference and DTA analyses are overly sensitive in regions of high- and low-dose gradient, respectively. The logical union of locations that fail both dose-difference and DTA acceptance criteria, termed the composite evaluation, is calculated and displayed. The composite evaluation provides a method for the physicist to efficiently identify regions that fail both the dose-difference and DTA acceptance criteria. The tool provides a computer platform for the quantitative comparison of calculated and measured dose distributions.

Entities:  

Mesh:

Year:  1998        PMID: 9800688     DOI: 10.1118/1.598363

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Canny edge-based deformable image registration.

Authors:  Vasant Kearney; Yihui Huang; Weihua Mao; Baohong Yuan; Liping Tang
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

2.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

3.  Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom.

Authors:  Scott E Davidson; Richard A Popple; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  A distance to dose difference tool for estimating the required spatial accuracy of a displacement vector field.

Authors:  Nahla K Saleh-Sayah; Elisabeth Weiss; Francisco J Salguero; Jeffrey V Siebers
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

5.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

6.  Predicting gamma evaluation results of patient-specific head and neck volumetric-modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study.

Authors:  Sangutid Thongsawad; Somyot Srisatit; Todsaporn Fuangrod
Journal:  J Appl Clin Med Phys       Date:  2022-05-18       Impact factor: 2.243

7.  Modification of the gamma function for the recognition of over- and under-dose regions in three dimensions.

Authors:  Mohammad Mohammadi; Nima Rostampour; Thomas P Rutten
Journal:  J Med Phys       Date:  2012-10

8.  Derivative based sensitivity analysis of gamma index.

Authors:  Biplab Sarkar; Anirudh Pradhan; T Ganesh
Journal:  J Med Phys       Date:  2015 Oct-Dec

9.  A comparison of anatomical and dosimetric variations in the first 15 fractions, and between fractions 16 and 25, of intensity-modulated radiotherapy for nasopharyngeal carcinoma.

Authors:  Haihua Yang; Yu Tu; Wei Wang; Wei Hu; Weijun Ding; Changhui Yu; Chao Zhou
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

10.  Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy.

Authors:  Nesrin Dogan; Ivaylo Mihaylov; Yan Wu; Paul J Keall; Jeffrey V Siebers; Michael P Hagan
Journal:  Radiat Oncol       Date:  2009-06-15       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.