Literature DB >> 9799831

Bone response to in vivo mechanical loading in two breeds of mice.

M P Akhter1, D M Cullen, E A Pedersen, D B Kimmel, R R Recker.   

Abstract

We investigated the bone response to external loading in C57BL/6J and C3H/HeJ mice, both breeds with low and high bone density, respectively. An in vivo tibial four-point bending device previously used for application of measured external loads in rats was adapted for mice. It delivered a uniform medio-lateral bending moment to the region of the tibia located 1-5.5 mm proximal to the tibio-fibula junction. The right legs of six C57BL/6J [low bone density (LBD)] and C3H/HeJ [high bone density (HBD)] mice were externally loaded in the device for 36 cycles/day at 2 Hz, 6 days/week for 2 weeks at 9.3 +/- 0.9 N force, inducing estimated lateral periosteal surface compressive strains of 5121 +/- 1128 mu epsilon in C3H/HeJ (HBD) mice (n = 6), significantly higher than the estimated 3988 +/- 820 mu epsilon in C57BL/6J mice (n = 6) (mean +/- SD). In addition, C3H/HeJ HBD mice (n = 11) were externally sham (pad pressure or no bending) loaded in the device for 36 cycles/day at 2 Hz, 3 days/week for 3 weeks at 9.3 +/- 0.9 N force. Calcein injections for bone labeling were given at the 10th and 3rd days before sacrifice. At the end of the experiment, all mice were killed and both tibiae were removed, fixed, embedded, and cross-sectioned through the loaded region. Both tibiae were measured for marrow area (Ma.Ar), cortical area (Ct.Ar), total area (Tt.Ar), cross-sectional moment of inertia (CSMI), and periosteal and endocortical woven bone surface (Wo.B/BS), single-labeled surface (sLS), double-labeled surface (dLS), and total formation surface (FS/BS). Differences in all variables due to breed and loading (both bending and sham-bending) were tested by two-way analysis of variance (ANOVA) (P < 0.05). Ma.Ar, Tt.Ar, and CSMI were greater in C57BL/6J (LBD) than in C3H/HeJ (HBD) mice. Periosteal and endocortical woven bone and formation surface were increased significantly more by loading (bending) in C57BL/6J than in C3H/HeJ mice. Periosteal woven bone response due to sham-bending or sham-loading was significantly lower than due to bending loads in the C3H/HeJ mice. We conclude that the bone response to external loading is greater in LBD mice than in HBD mice. The high bone density of C3H/HeJ (HBD) mice is related to breed-specific factors other than the response to loading.

Entities:  

Mesh:

Year:  1998        PMID: 9799831     DOI: 10.1007/s002239900554

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  46 in total

Review 1.  Fluoride's effects on the formation of teeth and bones, and the influence of genetics.

Authors:  E T Everett
Journal:  J Dent Res       Date:  2010-10-06       Impact factor: 6.116

2.  Decreased body weight in young Osterix-Cre transgenic mice results in delayed cortical bone expansion and accrual.

Authors:  Rachel A Davey; Michele V Clarke; Stephen Sastra; Jarrod P Skinner; Cherie Chiang; Paul H Anderson; Jeffrey D Zajac
Journal:  Transgenic Res       Date:  2011-12-13       Impact factor: 2.788

3.  Design and analysis of a novel mechanical loading machine for dynamic in vivo axial loading.

Authors:  James Macione; Sterling Nesbitt; Vaibhav Pandit; Shiva Kotha
Journal:  Rev Sci Instrum       Date:  2012-02       Impact factor: 1.523

4.  Exercise-induced changes in the cortical bone of growing mice are bone- and gender-specific.

Authors:  Joseph M Wallace; Rupak M Rajachar; Matthew R Allen; Susan A Bloomfield; Pamela G Robey; Marian F Young; David H Kohn
Journal:  Bone       Date:  2007-01-19       Impact factor: 4.398

5.  Cancellous bone adaptation to in vivo loading in a rabbit model.

Authors:  Marjolein C H van der Meulen; Timothy G Morgan; Xu Yang; Todd H Baldini; Elizabeth R Myers; Timothy M Wright; Mathias P G Bostrom
Journal:  Bone       Date:  2006-01-23       Impact factor: 4.398

6.  Alternative splicing in bone following mechanical loading.

Authors:  Sara M Mantila Roosa; Yunlong Liu; Charles H Turner
Journal:  Bone       Date:  2010-11-21       Impact factor: 4.398

7.  32 wk old C3H/HeJ mice actively respond to mechanical loading.

Authors:  Sandra L Poliachik; DeWayne Threet; Sundar Srinivasan; Ted S Gross
Journal:  Bone       Date:  2008-01-15       Impact factor: 4.398

Review 8.  Systems analysis of bone.

Authors:  Karl J Jepsen
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2009 Jul-Aug

9.  Fracture healing in mice lacking Pten in osteoblasts: a micro-computed tomography image-based analysis of the mechanical properties of the femur.

Authors:  Caitlyn J Collins; Juan F Vivanco; Scott A Sokn; Bart O Williams; Travis A Burgers; Heidi-Lynn Ploeg
Journal:  J Biomech       Date:  2014-11-28       Impact factor: 2.712

10.  Attenuated response to in vivo mechanical loading in mice with conditional osteoblast ablation of the connexin43 gene (Gja1).

Authors:  Susan K Grimston; Michael D Brodt; Matthew J Silva; Roberto Civitelli
Journal:  J Bone Miner Res       Date:  2008-06       Impact factor: 6.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.