A second generation of artificial cornea (Biokpro II).

J M Legeais1, G Renard.   

Abstract

The properties of a new second-generation colonizable artificial cornea were evaluated in humans. The prosthesis consisted of a peripheral rim of a translucent microporous fluorocarbon polymer (expanded polytetrafluoroethylene) fused with the polymer of the central optic. The optic was made of medical-grade polydimethylsiloxane coated with polyvinylpyrrolidone. Its refractive power was 42.2 diopters and it measured 7.0 mm in diameter and 0.55 mm in thickness. The geometry of the optic was tested by high-frequency ultrasound and intraocular pressure and distensibility were measured in an artificial chamber. Prostheses were implanted in one eye of 13 humans. The average follow-up was 6 months (range 3-9 months). Most of the eyes (11/13) were clinically stable after a 7 months follow up. Seven patients had visual acuity improvements. Mean corrected final visual acuity was 20/200 (range, 20/30 to light perception). Five anatomical failures occured (two extrusions, two retroprosthetic membranes, one endophthalmitis). The new optical core, junction, and surface properties of the polymers offer many advantages, quicker colonization of the supporting skirt, and an optical core with a geometry similar to that of a normal human cornea. Epithelial cells did not migrate over the interface and optical core. It seems that formation of an epithelium over the artificial device is essential for the long-term stability of the implant.

Entities:  

Mesh:

Year:  1998        PMID: 9794529     DOI: 10.1016/s0142-9612(98)00069-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

1.  Artificial corneas.

Authors:  B Allan
Journal:  BMJ       Date:  1999-03-27

2.  Hydroxyapatite promotes superior keratocyte adhesion and proliferation in comparison with current keratoprosthesis skirt materials.

Authors:  J S Mehta; C E Futter; S R Sandeman; R G A F Faragher; K A Hing; K E Tanner; B D S Allan
Journal:  Br J Ophthalmol       Date:  2005-10       Impact factor: 4.638

3.  Legeais BioKpro III keratoprosthesis implantation: long term results in seven patients.

Authors:  E J Hollick; S L Watson; J K G Dart; P J Luthert; B D S Allan
Journal:  Br J Ophthalmol       Date:  2006-09       Impact factor: 4.638

4.  Biocompatibility of poly(ethylene glycol) and poly(acrylic acid) interpenetrating network hydrogel by intrastromal implantation in rabbit cornea.

Authors:  Luo Luo Zheng; Vijay Vanchinathan; Roopa Dalal; Jaan Noolandi; Dale J Waters; Laura Hartmann; Jennifer R Cochran; Curtis W Frank; Charles Q Yu; Christopher N Ta
Journal:  J Biomed Mater Res A       Date:  2015-03-27       Impact factor: 4.396

Review 5.  The potential role of bioengineering and three-dimensional printing in curing global corneal blindness.

Authors:  Parker E Ludwig; Trevor J Huff; Jorge M Zuniga
Journal:  J Tissue Eng       Date:  2018-04-13       Impact factor: 7.813

6.  Biomimetic bone-like composites as osteo-odonto-keratoprosthesis skirt substitutes.

Authors:  Venkata Avadhanam; Ganesh Ingavle; Yishan Zheng; Sandeep Kumar; Christopher Liu; Susan Sandeman
Journal:  J Biomater Appl       Date:  2020-11-11       Impact factor: 2.646

  6 in total