Literature DB >> 9786640

Bite forces with mandibular implant-retained overdentures.

F A Fontijn-Tekamp1, A P Slagter, M A van't Hof, M E Geertman, W Kalk.   

Abstract

Sensitivity or pain of the mucoperiosteum covering the mandibular edentulous ridge is often thought to limit bite forces in complete-denture wearers. Therefore, bite forces with mandibular implant-retained overdentures may depend on the degree of implant support. This study analyzed the effects of different degrees of support for the mandibular denture on bite forces measured four years after denture treatment as part of a randomized controlled clinical trial. All subjects had received new maxillary dentures and (1) mainly implant-borne overdentures on a transmandibular implant (TMI), (2) mucosa-borne overdentures on two cylindric permucosal IMZ implants, or (3) new conventional dentures in the mandible. Fifty-three women and 15 men (mean age, 59.1 yrs; range, 41 to 77) participated in this trial. Both unilateral and bilateral bite forces were recorded at different positions with a miniature strain gauge transducer and a mechanical bite fork, respectively. The subjects were asked to bite at three force levels. Results indicated that women had significantly lower maximum bite forces than men. Persons with mandibular implant-retained overdentures had significantly higher unilateral and bilateral maximum bite forces than complete-denture wearers. However, bite forces did not differ between the mainly implant-borne (TMI) and mucosa-implant-borne (IMZ) implant systems. Therefore, it appears that differences in support for the mandibular overdenture by dental implants are not reflected in bite force capabilities.

Entities:  

Mesh:

Year:  1998        PMID: 9786640     DOI: 10.1177/00220345980770101101

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  8 in total

1.  Remodeling dynamics in the alveolar process in skeletally mature dogs.

Authors:  Sarandeep S Huja; Soledad A Fernandez; Kara J Hill; Yan Li
Journal:  Anat Rec A Discov Mol Cell Evol Biol       Date:  2006-12

2.  Force transfer and stress distribution in an implant-supported overdenture retained with a hader bar attachment: a finite element analysis.

Authors:  Preeti Satheesh Kumar; Kumar K S Satheesh; Jins John; Geetha Patil; Ruchi Patel
Journal:  ISRN Dent       Date:  2013-12-26

3.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

4.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08

5.  Developments in denture teeth to prevent softening by food solvents.

Authors:  Shakeel A Shahdad; John F McCabe; Robert W Wassell
Journal:  J Mater Sci Mater Med       Date:  2007-05-05       Impact factor: 4.727

6.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

7.  Evaluation of Maximum Bite Force in Patients with Complete Dentures.

Authors:  Kujtim Shala; Arlinda Tmava-Dragusha; Linda Dula; Teuta Pustina-Krasniqi; Teuta Bicaj; Enis Ahmedi; Zana Lila
Journal:  Open Access Maced J Med Sci       Date:  2018-03-13

8.  Assessment of the relationship between maximum occlusal force and median mandibular flexure in adults: A clinical trial study.

Authors:  Behnaz Ebadian; Majid Abolhasani; Anahita Heidarpour; Mohsen Ziaei; Mohammad Jowkar
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.