Literature DB >> 9786261

Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan.

D T Sato1, C D Goff, R T Gregory, K D Robinson, K A Carter, B R Herts, H B Vilsack, R G Gayle, F N Parent, R J DeMasi, G H Meier.   

Abstract

PURPOSE: The purpose of this study was to compare the accuracy of a color duplex ultrasound scan (CDU) to a computerized axial tomography scan (CT) in the diagnosis of endoleaks after stent graft repair of abdominal aortic aneurysms.
METHODS: The Endovascular Aneurysm Clinical Trial Core Laboratory records were reviewed from 117 concurrent CDU and CT studies that were performed in 79 patients who were implanted with the Endovascular Technologies stent graft device between December 1995 and January 1997. All of the studies were interpreted by the Core Laboratory as having the presence or the absence of an endoleak or as being indeterminate because of technical factors. Of the 117 videotaped CDU studies available for reexamination, 100 were reassessed for technical adequacy on the basis of the following criteria: a satisfactory imaging of the aneurysm sac and of the stent graft with gray scale, and both color and spectral Doppler scan evaluation for endoleak outside the endograft and within the aneurysm sac.
RESULTS: Of the 117 studies, 103 CDUs (88%) and 114 CTs (97%) were recorded as having the presence or the absence of an endoleak and 14 CDUs (12%) and 3 CTs (3%) were indeterminate. For the studies that were recorded to have the presence or the absence of an endoleak, the sensitivity, the specificity, the positive and the negative predictive values, and the accuracy of CDUs as compared with CTs were 97%, 74%, 66%, 98%, and 82%, respectively. Of the 100 CDU videotaped studies available for review, the following results were seen: (1) 93 CDUs had satisfactory B-mode images, (2) 76 had satisfactory color Doppler scan images to evaluate for endoleaks, (3) 55 had color Doppler scan assessment of the entire abdominal aortic aneurysm sac for endoleak, and (4) 27 had spectral Doppler scan waveform confirmation of suspected endoleaks. Only 19 CDU studies (19%) with all 4 criteria for complete assessment of endoleak were performed.
CONCLUSION: Although most of the CDU studies were technically suboptimal, the CDUs reliably identified endoleaks with an excellent sensitivity and a negative predictive value as compared with CT scans.

Entities:  

Mesh:

Year:  1998        PMID: 9786261     DOI: 10.1016/s0741-5214(98)70091-6

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Long-term follow-up of surgically excluded popliteal artery aneurysms with multi-slice CT angiography and Doppler ultrasound.

Authors:  Sebastien Deglise; Salah D Qanadli; Elena Rizzo; Nicolas Ducrey; Francesco Doenz; Claude Haller; Alban Denys; Jean-Marc Corpataux
Journal:  Eur Radiol       Date:  2006-01-17       Impact factor: 5.315

2.  Minilaparotomy for aortoiliac occlusive disease: preliminary results.

Authors:  Tomislav Klokocovnik; Tomislav Mirkovic; Tatjana Pintar; Viktor Videcnik
Journal:  Tex Heart Inst J       Date:  2002

Review 3.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

Review 4.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

5.  Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms.

Authors:  Mario Alerci; Michel Oberson; Antonella Fogliata; Augusto Gallino; Peter Vock; Rolf Wyttenbach
Journal:  Eur Radiol       Date:  2008-12-23       Impact factor: 5.315

Review 6.  The place of endovascular treatment in abdominal aortic aneurysm.

Authors:  Andreas Greiner; Jochen Grommes; Michael J Jacobs
Journal:  Dtsch Arztebl Int       Date:  2013-02-22       Impact factor: 5.594

Review 7.  Contrast-enhanced ultrasound after endovascular aortic repair-current status and future perspectives.

Authors:  Sasan Partovi; Mathias Kaspar; Markus Aschwanden; Charles Lopresti; Shivanshu Madan; Heiko Uthoff; Stephan Imfeld; Daniel Staub
Journal:  Cardiovasc Diagn Ther       Date:  2015-12

Review 8.  Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods?

Authors:  Karolina Stefaniak; Michal Stanisic; Marcin Gabriel; Grzegorz Oszkinis
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-02-11       Impact factor: 1.426

  8 in total