Literature DB >> 9783268

Small photon field dosimetry for stereotactic radiosurgery.

D M Duggan1, C W Coffey.   

Abstract

Performing and assuring the quality of the planning and delivery of stereotactic radiosurgery with photon beams requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratios and off-axis ratios, and measurement of actual dose distributions from simulated treatments. For the small photon fields used in radiosurgery, these measurements require special equipment and techniques, which are described in this review.

Mesh:

Year:  1998        PMID: 9783268     DOI: 10.1016/s0958-3947(98)00013-2

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  10 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  Evaluation of beam modeling for small fields using a flattening filter-free beam.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Takeo Nakashima; Masamichi Aita; Shintaro Tsuda; Yusuke Ochi; Takuro Okumura; Hirokazu Masuda; Yoshimi Ohno; Yuji Murakami; Yasushi Nagata
Journal:  Radiol Phys Technol       Date:  2016-06-21

3.  Dosimetric comparison of linear accelerator-based stereotactic radiosurgery systems.

Authors:  S D Sharma; Sudhir Kumar; S S Dagaonkar; Geetika Bisht; S Dayanand; Reena Devi; S S Deshpande; S Chaudhary; B C Bhatt; S Kannan
Journal:  J Med Phys       Date:  2007-01

4.  Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry.

Authors:  Wook Jae Yoo; Jinsoo Moon; Kyoung Won Jang; Ki-Tek Han; Sang Hun Shin; Dayeong Jeon; Jang-Yeon Park; Byung Gi Park; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2012-05-14       Impact factor: 3.576

5.  Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.

Authors:  Teh Lin; Lu Wang; C-M Charlie Ma
Journal:  J Med Phys       Date:  2022-03-31

6.  SciFi detector and associated method for real-time determination of profile and output factor for small fields in stereotactic radiotherapy.

Authors:  P Pittet; J Esteves; J-M Galvan; G-N Lu; F Blanc; G Haefeli; P Hopchev; S Rit; L Desbat; J Ribouton; P Jalade
Journal:  Med Phys       Date:  2020-01-30       Impact factor: 4.071

7.  Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods.

Authors:  S A Rahimi; B Hashemi; S R Mahdavi
Journal:  J Biomed Phys Eng       Date:  2019-02-01

8.  Patient-specific dose quality assurance of single-isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D.

Authors:  James McCulloch; Jamie Pawlowski; Neil Kirby; Karl Rasmussen; Zheng Shi; Pamela Myers; Sotirios Stathakis; Niko Papanikolaou; Daniel L Saenz
Journal:  J Appl Clin Med Phys       Date:  2020-07-18       Impact factor: 2.102

9.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep

10.  High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation.

Authors:  Sree Bash Chandra Debnath; Carole Fauquet; Agnes Tallet; Anthony Goncalves; Sébastien Lavandier; Franck Jandard; Didier Tonneau; Julien Darreon
Journal:  Med Phys       Date:  2020-01-23       Impact factor: 4.071