Literature DB >> 9776501

Continuous, less invasive, hemodynamic monitoring in intensive care after cardiac surgery.

O Gödje1, K Höke, P Lamm, C Schmitz, C Thiel, M Weinert, B Reichart.   

Abstract

A pulse-contour-based method for continuous measurement of cardiac output (CO) and systemic vascular resistance (SVR) was tested and arterial thermodilution, used for calibration, was compared to pulmonary artery thermodilution. In 30 patients CO and SVR were measured by pulse contour analysis (COpc, SVRpc) 270 times in 24 h and compared to arterial (COart, SVRart) and pulmonary arterial (COpa, SVRpa) thermodilution measurements. The mean difference between COpa and COart was 0.26 L/min (3.6%) with a standard deviation (SD) of 0.7 L/min, the correlation coefficient was 0.96, and the coefficient of variation was 5.0% and 5.9% respectively. COpc did differ from COpa by 0.11 L/min (1.5%, SD = 0.6 L/min) and from COart by 0.15 L/min (2.1%, SD = 0.7 L/min). Correlation of COpc with COpa was 0.91, correlation of COpc with COart was 0.90. SVRpc did correlate with SVRpa, a coefficient of 0.94, and with SVRart, a coefficient of 0.92. Mean COpc and SVRpc did not differ significantly from COpa or COart and SVRpa or SVRart during the 24 h study period. It is concluded that COart correlates well with COpa and can be used to calibrate COpc. COpc and SVRpc agree with thermodilution-based CO and SVR without recalibration for 24 hours.

Entities:  

Mesh:

Year:  1998        PMID: 9776501     DOI: 10.1055/s-2007-1010233

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  11 in total

1.  Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.

Authors:  M Rupérez; J López-Herce; C García; C Sánchez; E García; D Vigil
Journal:  Pediatr Cardiol       Date:  2003-12-23       Impact factor: 1.655

2.  Effects of continuous negative extra-abdominal pressure on cardiorespiratory function during abdominal hypertension: an experimental study.

Authors:  Franco Valenza; Manuela Irace; Massimiliano Guglielmi; Stefano Gatti; Nicola Bottino; Cecilia Tedesco; Micol Maffioletti; Patrizia Maccagni; Tommaso Fossali; Gabriele Aletti; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2004-10-26       Impact factor: 17.440

3.  [Accuracy of pulse contour cardiac index measurements during changes of preload and aortic impedance].

Authors:  T W Felbinger; M S Goepfert; T Goresch; A E Goetz; D A Reuter
Journal:  Anaesthesist       Date:  2005-08       Impact factor: 1.041

4.  Stroke volume variation as a guide to fluid administration in morbidly obese patients undergoing laparoscopic bariatric surgery.

Authors:  Anil Kumar Jain; Amitabh Dutta
Journal:  Obes Surg       Date:  2010-03-09       Impact factor: 4.129

Review 5.  [Aneurysmal subarachnoid hemorrhage. Significance and complications].

Authors:  A S Sarrafzadeh; U Kaisers; W Boemke
Journal:  Anaesthesist       Date:  2007-09       Impact factor: 1.041

6.  Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock.

Authors:  F Spöhr; P Hettrich; H Bauer; U Haas; E Martin; B W Böttiger
Journal:  Intensive Care Med       Date:  2007-06-05       Impact factor: 17.440

7.  Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM).

Authors:  S Romagnoli; S Bevilacqua; C Lazzeri; F Ciappi; D Dini; C Pratesi; G F Gensini; S M Romano
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

8.  Accuracy of a novel approach to measuring arterial thermodilution cardiac output during intra-aortic counterpulsation.

Authors:  Werner Baulig; Philipp Schuett; Oliver Goedje; Edith R Schmid
Journal:  J Clin Monit Comput       Date:  2007-03-17       Impact factor: 1.977

9.  Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients.

Authors:  Michael Sander; Christian von Heymann; Achim Foer; Vera von Dossow; Joachim Grosse; Simon Dushe; Wolfgang F Konertz; Claudia D Spies
Journal:  Crit Care       Date:  2005-11-04       Impact factor: 9.097

10.  Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial.

Authors:  Ole Broch; Jose Carbonell; Carlos Ferrando; Malte Metzner; Arne Carstens; Martin Albrecht; Matthias Gruenewald; Jan Höcker; Marina Soro; Markus Steinfath; Jochen Renner; Berthold Bein
Journal:  BMC Anesthesiol       Date:  2015-11-26       Impact factor: 2.217

View more