Literature DB >> 9773874

Quantitative flow cytometry: inter-laboratory variation.

V E Zenger1, R Vogt, F Mandy, A Schwartz, G E Marti.   

Abstract

Quantitative flow cytometry (QFCM) offers a means of standardization within and between flow cytometers. QFCM parameters were set by determining the antibody-binding capacity (ABC) of CD4, CD8, and CD3 cells from 10 normal donors with the use of eight FACScan flow cytometers. QC3 beads and a certified blank bead were used to set up the instruments. Fluorescein isothiocyanate (FITC) conjugated to molecular equivalents of soluble fluorochrome (MESF) microbead standards was used before and after the donor samples were run to ensure that the machines were operating consistently. Lyophilized cells (Cytotrol) were used as a target, to control for antigen expression in the cell preparation. Quantitative Simply Cellular (QSC) beads were used to establish a standard calibration curve for each of the FITC and phycoerythrin antibody conjugates on each of the instruments. Single-parameter fluorescent histograms derived from list-mode files were used to calculate the slope (coefficient of response), intercept (zero channel), number of channels per decade, and ABC or MESF threshold (blank bead). The fluorescence intensity (geometric mean) of the positive and negative donor cell populations was compared with the standard curves, and the ABCs were calculated. The results show consistent instrument performance between laboratories. However, after standardization of CD3, CD4, and CD8 ABCs to microbeads, large variations were noted between donors and laboratories. The source of this variation does not appear to be in the instrumentation but may be due to the lack of an unified set-up protocol, introducing issues of antibody saturation, methods for whole blood lysis and fixation, and the behavior of the microbead standards.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9773874     DOI: 10.1002/(sici)1097-0320(19981001)33:2<138::aid-cyto8>3.0.co;2-f

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  18 in total

1.  Quality assurance for polychromatic flow cytometry using a suite of calibration beads.

Authors:  Stephen P Perfetto; David Ambrozak; Richard Nguyen; Pratip K Chattopadhyay; Mario Roederer
Journal:  Nat Protoc       Date:  2012-11-08       Impact factor: 13.491

Review 2.  Spectral flow cytometry.

Authors:  John P Nolan; Danilo Condello
Journal:  Curr Protoc Cytom       Date:  2013-01

3.  Improved quantitative detection of biotin-labeled red blood cells by flow cytometry.

Authors:  Albert D Donnenberg; Tamir Kanias; Darrell J Triulzi; Catherine J Dennis; E Michael Meyer; Mark Gladwin
Journal:  Transfusion       Date:  2019-06-06       Impact factor: 3.337

4.  Development of a consensus protocol to quantify primate anti-non-Gal xenoreactive antibodies using pig aortic endothelial cells.

Authors:  Agnes M Azimzadeh; Guerard W Byrne; Mohamed Ezzelarab; Emily Welty; Gheorghe Braileanu; Xiangfei Cheng; Simon C Robson; Christopher G A McGregor; David K C Cooper; Richard N Pierson
Journal:  Xenotransplantation       Date:  2014-09-01       Impact factor: 3.907

5.  Transcriptome-wide noise controls lineage choice in mammalian progenitor cells.

Authors:  Hannah H Chang; Martin Hemberg; Mauricio Barahona; Donald E Ingber; Sui Huang
Journal:  Nature       Date:  2008-05-22       Impact factor: 49.962

6.  Standardized method to minimize variability in a functional P2X(7) flow cytometric assay for a multi-center clinical trial.

Authors:  N L Korpi-Steiner; D Sheerar; E B Puffer; C Urben; J Boyd; A Guadarrama; K Schell; L C Denlinger
Journal:  Cytometry B Clin Cytom       Date:  2008-09       Impact factor: 3.058

7.  Quantitative measurement of multifunctional quantum dot binding to cellular targets using flow cytometry.

Authors:  R A Smith; T D Giorgio
Journal:  Cytometry A       Date:  2009-05       Impact factor: 4.355

Review 8.  Deconstructing stem cell population heterogeneity: single-cell analysis and modeling approaches.

Authors:  Jincheng Wu; Emmanuel S Tzanakakis
Journal:  Biotechnol Adv       Date:  2013-09-11       Impact factor: 14.227

9.  DNA-directed assembly of antibody-fluorophore conjugates for quantitative multiparametric flow cytometry.

Authors:  Amy C Flor; Jimmy H Williams; Kelly M Blaine; Ryan C Duggan; Anne I Sperling; David A Schwartz; Stephen J Kron
Journal:  Chembiochem       Date:  2013-12-27       Impact factor: 3.164

10.  Evaluation of Exosome Proteins by on-Bead Flow Cytometry.

Authors:  Marie-Nicole Theodoraki; Chang-Sook Hong; Vera S Donnenberg; Albert D Donnenberg; Theresa L Whiteside
Journal:  Cytometry A       Date:  2020-08-21       Impact factor: 4.714

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.