Literature DB >> 9766858

Detection of 4-hydroxycoumarin anticoagulants and their metabolites in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons by gas chromatography-mass spectrometry after extractive methylation.

H H Maurer1, J W Arlt.   

Abstract

A gas chromatography-mass spectrometry (GC-MS) procedure was developed for the detection of 4-hydroxycoumarin anticoagulants and their metabolites in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons after extractive methylation. The part of the phase-transfer catalyst remaining in the organic phase was removed by solid-phase extraction on a diol phase. The compounds were separated by capillary GC and identified by computerized MS in the full scan mode. Using mass chromatography with the ions m/z 291, 294, 295, 309, 313, 322, 324, 336, 343 and 354, the possible presence of 4-hydroxycoumarin anticoagulants and/or their metabolites could be indicated. The identity of positive signals in such mass chromatograms was confirmed by comparison of the peaks underlying full mass spectra with the reference spectra recorded during this study. This method allowed the detection of therapeutic concentrations of phenprocoumon and warfarin in human urine samples. In absence of human urine, acenocoumarol, coumachlor, coumatetrayl, pyranocoumarin (cyclocumarol) could be detected only in rat urine.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9766858     DOI: 10.1016/s0378-4347(98)00243-6

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  5 in total

1.  3-Acetyl-4-hy-droxy-6,7-dimethyl-2H-chromen-2-one.

Authors:  Mohammad Asad; Chuan-Wei Oo; Hasnah Osman; Jia Hao Goh; Hoong-Kun Fun
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2010-11-13

2.  Crystal structure of 2-oxo-2H-chromen-3-yl propano-ate.

Authors:  Eric Ziki; Jules Yoda; Abdoulaye Djandé; Adama Saba; Rita Kakou-Yao
Journal:  Acta Crystallogr E Crystallogr Commun       Date:  2016-10-11

3.  Crystal structure of 2-oxo-2H-chromen-3-yl 4-chloro-benzoate and Hirshfeld surface analysis.

Authors:  Eric Ziki; Siaka Sosso; Frédérica Mansilla-Koblavi; Abdoulaye Djandé; Rita Kakou-Yao
Journal:  Acta Crystallogr E Crystallogr Commun       Date:  2017-01-01

4.  Development of a Fluorescent Microfluidic Device Based on Antibody Microarray Read-Out for Therapeutic Drug Monitoring of Acenocoumarol.

Authors:  J-Pablo Salvador; Thomas Brettschneider; Christian Dorrer; M-Pilar Marco
Journal:  Front Bioeng Biotechnol       Date:  2022-03-29

5.  Potentiometric Sensors for Iodide and Bromide Based on Pt(II)-Porphyrin.

Authors:  Dana Vlascici; Nicoleta Plesu; Gheorghe Fagadar-Cosma; Anca Lascu; Mihaela Petric; Manuela Crisan; Anca Belean; Eugenia Fagadar-Cosma
Journal:  Sensors (Basel)       Date:  2018-07-16       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.